The TU-SHAN Electric Type 2 AC Surge Protective Device 10kA 20kA is designed for AC power distribution systems where transient overvoltage protection is required. Its compact DIN rail design, built-in thermal disconnection and visual status window support installation and routine inspection in compatible electrical panels.
TU-SHAN Electric | TYPE 2 AC SPD
Transient overvoltages can reach branch circuits, control cabinets and electronic equipment through the AC power supply. The Type 2 AC Surge Protective Device 10kA 20kA is designed for downstream surge protection, helping project teams add a dedicated protection stage closer to the equipment they need to safeguard.
With a stated 10kA nominal discharge current, 20kA maximum discharge current and 18mm single-module width, the TZU5-D offers a compact option for compatible distribution boards and equipment enclosures. The available 1P+NPE configuration can be considered for suitable single-phase AC installations.

Discharge current ratings use the 8/20μs waveform. Confirm the exact rated voltage, protection level and pole configuration against the applicable product datasheet before ordering.
Use the following specifications as a starting point for technical review. The selected configuration and its official datasheet should be checked before the product is approved for a project.
| Parameter | Specification |
| Brand | TU-SHAN Electric |
| Model | TZU5-D |
| Product Type | Type 2 AC Surge Protective Device |
| Available Configuration | 1P, 1P+N, 1P+NPE, 2P, 3P and 4P options listed; confirm availability for the exact version |
| Maximum Continuous Operating Voltage (Uc) | Approximately 275V AC; confirm rated value |
| Nominal Discharge Current (In) | 10kA (8/20μs) |
| Maximum Discharge Current (Imax) | 20kA (8/20μs) |
| Voltage Protection Level (Up) | ≤1.0kV; confirm for the selected configuration |
| Protection Technology | Metal Oxide Varistor (MOV) |
| Disconnection Mechanism | Built-in thermal disconnection |
| Status Indication | Visual status window |
| Mounting | 35mm DIN rail |
| Single-Module Width | 18mm |
| Protection Rating | IP20 |
| Operating Temperature | Refer to the official product datasheet |
| Referenced Standards | GB 18802.1, IEC 61643.1 as listed in the supplied product information; verify applicable editions and evidence |
The 18mm single-module width helps installers plan rail space in compact distribution boards and equipment enclosures. Check the complete pole configuration and accessory requirements when calculating the total installation width.
The metal oxide varistor changes its electrical behavior during a transient overvoltage, allowing surge current to pass through the designated protection path. Correct earthing and coordinated protection remain essential.
The status window provides a visible indication for routine maintenance. Personnel should interpret the indicator according to the markings and instructions supplied with the actual product.

For a compatible single-phase AC installation, the 1P+NPE configuration is intended to provide surge protection through the designated line and neutral-to-protective-earth paths. The exact internal topology and terminal connections must follow the manufacturer's wiring diagram and the electrical system design.
Under normal operating conditions, the MOV protection element presents high impedance. When a transient overvoltage occurs, its impedance decreases and allows surge current to be diverted through the designated path. Once the transient passes, a functioning MOV returns to a high-impedance state.
An SPD does not replace protective earthing, insulation coordination or other electrical safety measures. Its effectiveness depends on correct installation and coordination with the wider protection system.
The TZU5-D can be considered for compatible downstream AC power circuits where a compact Type 2 SPD is required. The following examples describe potential applications, not a guarantee of suitability for every installation.
Branch panels, floor-level distribution boards and office power circuits can incorporate a downstream SPD as part of a coordinated surge protection design.
CCTV power supplies, access-control equipment and alarm system power circuits may benefit from appropriately selected protection against transients entering through the AC supply.
Small PLCs, measurement instruments, sensors and control panels contain electronic components that can be affected by transient overvoltages on their power circuits.
Suitable cabinets serving shops, offices, hotels and roadside monitoring equipment may use this type of SPD when the electrical ratings and installation conditions match the project requirements.

Important: The IP20-rated device is intended for installation inside a suitable enclosure, not direct exposure to rain or outdoor weather. The TZU5-D protects AC power circuits; Ethernet, communication, antenna and signal lines may require separately selected surge protection devices.
Surge protection is generally planned around the installation's incoming supply, distribution stages and protected equipment. The TZU5-D is intended mainly for downstream protection, rather than serving as the only SPD at a building's incoming supply.
| Selection Point | TZU5-D | Upstream SPD |
| Typical design role | Downstream branch circuits and selected equipment power supplies | Incoming or upstream distribution, as determined by the protection design |
| Discharge-current selection | Stated In 10kA and Imax 20kA | Selected according to lightning exposure, system design and required ratings |
| What to check | Uc, Up, pole configuration and compatibility with the protected circuit | Required SPD type, discharge capacity, backup protection and coordination |
A higher-capacity model such as the TU-SHAN Electric TZU5-C may be considered for an upstream position where its verified specifications suit the design. The two devices should not be combined solely on the basis of their current ratings. Cable distance, upstream protection, surge exposure and the withstand voltage of connected equipment all affect coordination.
For project installations, the backup fuse or circuit breaker must follow the manufacturer's instructions and the applicable electrical design. Long SPD connection leads can increase the residual voltage at the protected equipment, so conductor routing deserves attention during installation.
The TZU5-D has a visual status window and a built-in thermal disconnection mechanism. These features support status inspection and help disconnect an affected module when internal deterioration or overheating reaches the mechanism's operating threshold. They do not eliminate all electrical or fire risks.
The supplied product information identifies green as the normal status and a changed indication as a possible replacement warning. Always follow the actual product markings and service instructions. If the indicator signals failure or end of life, arrange safe isolation and replacement in accordance with the applicable procedures.
The supplied product information references GB 18802.1 and IEC 61643.1. For engineering approval or bulk procurement, request the documents applicable to the exact model and configuration.
The available documentation should be confirmed with TU-SHAN Electric before final project approval. No test report or certification should be assumed from the standard references alone.

To reduce selection errors and avoid unnecessary back-and-forth during quotation, share the electrical system details and the intended installation point. This helps identify which configuration and technical documents need to be confirmed before an order is placed.
| Information Required | Details to Provide |
| AC supply | Nominal voltage and frequency |
| Earthing arrangement | TN-S, TN-C-S or another specified system |
| Pole configuration | 1P, 1P+N, 1P+NPE, 2P, 3P or 4P, subject to model availability |
| Installation point | Branch distribution board, terminal cabinet or equipment power circuit |
| Existing protection | Upstream SPD model and backup fuse or circuit breaker, if known |
| Technical documents | Required datasheet, wiring diagram and test records |
| Order quantity | Sample quantity or estimated production quantity |
Looking for a compact Type 2 AC surge protective device for a distribution board, security cabinet or control circuit? Send TU-SHAN Electric your required pole configuration, rated supply voltage, installation details and expected quantity.
We can review the information provided and confirm the applicable product specifications and available technical documentation before you finalize your selection.
It is a Type 2 AC surge protective device intended mainly for downstream distribution circuits and equipment power supplies. The stated nominal discharge current is 10kA and the maximum discharge current is 20kA, using the 8/20μs waveform.
A 1P+NPE version is listed as available. Confirm the supply voltage, earthing arrangement, internal circuit and terminal wiring against the exact product datasheet before installation.
It is primarily intended for downstream protection. The main incoming SPD must be selected according to the installation's lightning protection design, required SPD type, earthing arrangement and discharge-current requirements.
The TZU5-D is positioned as a compact downstream protection option. The TZU5-C may be considered for an upstream position when its verified ratings match the design. Confirm both models' specifications and their coordination requirements before selecting a combination.
No. This product is intended for AC power protection. Ethernet, communication, antenna and signal circuits may require separate surge protective devices selected for their respective interfaces.
The required backup fuse or circuit breaker depends on the product instructions and installation design. Confirm the permitted device type and rating before installation.
Confirm the rated voltage, pole configuration, terminal arrangement, Up value, required documentation and order quantity. Providing the intended application and existing protection details also helps with technical review.
Contact TU-SHAN Electric with your project requirements for the TZU5-D. Include the supply voltage, pole configuration, installation location and expected quantity so the product version and available documentation can be reviewed for your application.