Type 2 AC Surge Protective Device 10kA 20kA
  • Type 2 AC Surge Protective Device 10kA 20kAType 2 AC Surge Protective Device 10kA 20kA
  • Type 2 AC Surge Protective Device 10kA 20kAType 2 AC Surge Protective Device 10kA 20kA
  • Type 2 AC Surge Protective Device 10kA 20kAType 2 AC Surge Protective Device 10kA 20kA
  • Type 2 AC Surge Protective Device 10kA 20kAType 2 AC Surge Protective Device 10kA 20kA
  • Type 2 AC Surge Protective Device 10kA 20kAType 2 AC Surge Protective Device 10kA 20kA
  • Type 2 AC Surge Protective Device 10kA 20kAType 2 AC Surge Protective Device 10kA 20kA
  • Type 2 AC Surge Protective Device 10kA 20kAType 2 AC Surge Protective Device 10kA 20kA
  • Type 2 AC Surge Protective Device 10kA 20kAType 2 AC Surge Protective Device 10kA 20kA
  • Type 2 AC Surge Protective Device 10kA 20kAType 2 AC Surge Protective Device 10kA 20kA
  • Type 2 AC Surge Protective Device 10kA 20kAType 2 AC Surge Protective Device 10kA 20kA
  • Type 2 AC Surge Protective Device 10kA 20kAType 2 AC Surge Protective Device 10kA 20kA
  • Type 2 AC Surge Protective Device 10kA 20kAType 2 AC Surge Protective Device 10kA 20kA
  • Type 2 AC Surge Protective Device 10kA 20kAType 2 AC Surge Protective Device 10kA 20kA
  • Type 2 AC Surge Protective Device 10kA 20kAType 2 AC Surge Protective Device 10kA 20kA

Type 2 AC Surge Protective Device 10kA 20kA

The TU-SHAN Electric Type 2 AC Surge Protective Device 10kA 20kA is designed for AC power distribution systems where transient overvoltage protection is required. Its compact DIN rail design, built-in thermal disconnection and visual status window support installation and routine inspection in compatible electrical panels.

  • Type 2 protection for compatible AC distribution and branch circuits
  • 1P+NPE configuration for suitable single-phase installations
  • MOV-based protection with built-in thermal disconnection
  • Visual status window for checking the device condition
  • 35 mm DIN rail mounting for electrical distribution enclosures
Product Type Type 2 AC SPD
Pole Configuration 1P+NPE
Nominal Discharge Current In 10 kA
Maximum Discharge Current Imax 20 kA

TU-SHAN Electric | TYPE 2 AC SPD

Protect Downstream Circuits with the TZU5-D Surge Protective Device

Transient overvoltages can reach branch circuits, control cabinets and electronic equipment through the AC power supply. The Type 2 AC Surge Protective Device 10kA 20kA is designed for downstream surge protection, helping project teams add a dedicated protection stage closer to the equipment they need to safeguard.

With a stated 10kA nominal discharge current, 20kA maximum discharge current and 18mm single-module width, the TZU5-D offers a compact option for compatible distribution boards and equipment enclosures. The available 1P+NPE configuration can be considered for suitable single-phase AC installations.

Check Specifications & Configuration

TUZHAN Electric TZU5-D Type 2 AC surge protective device front viewTUZHAN Electric TZU5-D modular AC surge protector detail

Key Specifications at a Glance

10kA Nominal Discharge Current
20kA Maximum Discharge Current
18mm Single-Module Width
35mm DIN Rail Mounting

Discharge current ratings use the 8/20μs waveform. Confirm the exact rated voltage, protection level and pole configuration against the applicable product datasheet before ordering.

TZU5-D Electrical Specifications

Use the following specifications as a starting point for technical review. The selected configuration and its official datasheet should be checked before the product is approved for a project.

Parameter Specification
Brand TU-SHAN Electric
Model TZU5-D
Product Type Type 2 AC Surge Protective Device
Available Configuration 1P, 1P+N, 1P+NPE, 2P, 3P and 4P options listed; confirm availability for the exact version
Maximum Continuous Operating Voltage (Uc) Approximately 275V AC; confirm rated value
Nominal Discharge Current (In) 10kA (8/20μs)
Maximum Discharge Current (Imax) 20kA (8/20μs)
Voltage Protection Level (Up) ≤1.0kV; confirm for the selected configuration
Protection Technology Metal Oxide Varistor (MOV)
Disconnection Mechanism Built-in thermal disconnection
Status Indication Visual status window
Mounting 35mm DIN rail
Single-Module Width 18mm
Protection Rating IP20
Operating Temperature Refer to the official product datasheet
Referenced Standards GB 18802.1, IEC 61643.1 as listed in the supplied product information; verify applicable editions and evidence
Before technical approval: Confirm Uc, Up, the internal circuit, terminal arrangement and applicable standard documentation for the exact model. The approximate Uc value above should not be treated as a final rated value.

Why Consider the TZU5-D for Downstream Protection?

Compact Cabinet Layout

The 18mm single-module width helps installers plan rail space in compact distribution boards and equipment enclosures. Check the complete pole configuration and accessory requirements when calculating the total installation width.

MOV-Based Surge Protection

The metal oxide varistor changes its electrical behavior during a transient overvoltage, allowing surge current to pass through the designated protection path. Correct earthing and coordinated protection remain essential.

Visual Status Inspection

The status window provides a visible indication for routine maintenance. Personnel should interpret the indicator according to the markings and instructions supplied with the actual product.

TUZHAN Electric TZU5-D AC surge protection device product detailTZU5-D modular surge protective device construction detail

How the 1P+NPE Configuration Works

For a compatible single-phase AC installation, the 1P+NPE configuration is intended to provide surge protection through the designated line and neutral-to-protective-earth paths. The exact internal topology and terminal connections must follow the manufacturer's wiring diagram and the electrical system design.

Under normal operating conditions, the MOV protection element presents high impedance. When a transient overvoltage occurs, its impedance decreases and allows surge current to be diverted through the designated path. Once the transient passes, a functioning MOV returns to a high-impedance state.

Installation points to verify

  • Confirm supply voltage, earthing arrangement and the selected SPD configuration.
  • Follow the approved wiring diagram and applicable electrical installation requirements.
  • Keep connecting conductors short and direct wherever practicable to limit additional residual voltage.
  • Check the required backup fuse or circuit breaker against the manufacturer's instructions.

An SPD does not replace protective earthing, insulation coordination or other electrical safety measures. Its effectiveness depends on correct installation and coordination with the wider protection system.

Suitable Applications for the TZU5-D

The TZU5-D can be considered for compatible downstream AC power circuits where a compact Type 2 SPD is required. The following examples describe potential applications, not a guarantee of suitability for every installation.

Distribution Boards

Branch panels, floor-level distribution boards and office power circuits can incorporate a downstream SPD as part of a coordinated surge protection design.

CCTV and Security Cabinets

CCTV power supplies, access-control equipment and alarm system power circuits may benefit from appropriately selected protection against transients entering through the AC supply.

Instrumentation and Control

Small PLCs, measurement instruments, sensors and control panels contain electronic components that can be affected by transient overvoltages on their power circuits.

Commercial Equipment Enclosures

Suitable cabinets serving shops, offices, hotels and roadside monitoring equipment may use this type of SPD when the electrical ratings and installation conditions match the project requirements.

TUZHAN Electric TZU5-D surge protective device for distribution and control cabinetsTZU5-D Type 2 AC SPD product detail for electrical equipment enclosures

Important: The IP20-rated device is intended for installation inside a suitable enclosure, not direct exposure to rain or outdoor weather. The TZU5-D protects AC power circuits; Ethernet, communication, antenna and signal lines may require separately selected surge protection devices.

Choosing Between the TZU5-D and an Upstream SPD

Surge protection is generally planned around the installation's incoming supply, distribution stages and protected equipment. The TZU5-D is intended mainly for downstream protection, rather than serving as the only SPD at a building's incoming supply.

Selection Point TZU5-D Upstream SPD
Typical design role Downstream branch circuits and selected equipment power supplies Incoming or upstream distribution, as determined by the protection design
Discharge-current selection Stated In 10kA and Imax 20kA Selected according to lightning exposure, system design and required ratings
What to check Uc, Up, pole configuration and compatibility with the protected circuit Required SPD type, discharge capacity, backup protection and coordination

A higher-capacity model such as the TU-SHAN Electric TZU5-C may be considered for an upstream position where its verified specifications suit the design. The two devices should not be combined solely on the basis of their current ratings. Cable distance, upstream protection, surge exposure and the withstand voltage of connected equipment all affect coordination.

For project installations, the backup fuse or circuit breaker must follow the manufacturer's instructions and the applicable electrical design. Long SPD connection leads can increase the residual voltage at the protected equipment, so conductor routing deserves attention during installation.

Inspection, Replacement and Technical Records

The TZU5-D has a visual status window and a built-in thermal disconnection mechanism. These features support status inspection and help disconnect an affected module when internal deterioration or overheating reaches the mechanism's operating threshold. They do not eliminate all electrical or fire risks.

The supplied product information identifies green as the normal status and a changed indication as a possible replacement warning. Always follow the actual product markings and service instructions. If the indicator signals failure or end of life, arrange safe isolation and replacement in accordance with the applicable procedures.

Documentation for Project Approval

The supplied product information references GB 18802.1 and IEC 61643.1. For engineering approval or bulk procurement, request the documents applicable to the exact model and configuration.

  • Product datasheet and wiring diagram
  • Applicable standard editions and compliance evidence
  • Relevant electrical performance or surge test records, where available
  • Inspection and traceability records, where maintained

The available documentation should be confirmed with TU-SHAN Electric before final project approval. No test report or certification should be assumed from the standard references alone.

TUZHAN Electric TZU5-D AC surge protective device inspection and product detailTZU5-D Type 2 AC surge protector for technical product evaluation

Ordering the Correct TZU5-D Configuration

To reduce selection errors and avoid unnecessary back-and-forth during quotation, share the electrical system details and the intended installation point. This helps identify which configuration and technical documents need to be confirmed before an order is placed.

Information Required Details to Provide
AC supply Nominal voltage and frequency
Earthing arrangement TN-S, TN-C-S or another specified system
Pole configuration 1P, 1P+N, 1P+NPE, 2P, 3P or 4P, subject to model availability
Installation point Branch distribution board, terminal cabinet or equipment power circuit
Existing protection Upstream SPD model and backup fuse or circuit breaker, if known
Technical documents Required datasheet, wiring diagram and test records
Order quantity Sample quantity or estimated production quantity

Request a TZU5-D Quotation

Looking for a compact Type 2 AC surge protective device for a distribution board, security cabinet or control circuit? Send TU-SHAN Electric your required pole configuration, rated supply voltage, installation details and expected quantity.

We can review the information provided and confirm the applicable product specifications and available technical documentation before you finalize your selection.

Send Your Inquiry

Frequently Asked Questions

What type of surge protective device is the TZU5-D?

It is a Type 2 AC surge protective device intended mainly for downstream distribution circuits and equipment power supplies. The stated nominal discharge current is 10kA and the maximum discharge current is 20kA, using the 8/20μs waveform.

Is the Type 2 AC Surge Protective Device 10kA 20kA suitable for a 1P+NPE single-phase circuit?

A 1P+NPE version is listed as available. Confirm the supply voltage, earthing arrangement, internal circuit and terminal wiring against the exact product datasheet before installation.

Can the TZU5-D be used as the only SPD at the main incoming supply?

It is primarily intended for downstream protection. The main incoming SPD must be selected according to the installation's lightning protection design, required SPD type, earthing arrangement and discharge-current requirements.

What is the difference between the TZU5-D and TZU5-C?

The TZU5-D is positioned as a compact downstream protection option. The TZU5-C may be considered for an upstream position when its verified ratings match the design. Confirm both models' specifications and their coordination requirements before selecting a combination.

Does the TZU5-D protect Ethernet and communication lines?

No. This product is intended for AC power protection. Ethernet, communication, antenna and signal circuits may require separate surge protective devices selected for their respective interfaces.

Does the Surge Protective Device require backup overcurrent protection?

The required backup fuse or circuit breaker depends on the product instructions and installation design. Confirm the permitted device type and rating before installation.

What should I confirm before placing a bulk order?

Confirm the rated voltage, pole configuration, terminal arrangement, Up value, required documentation and order quantity. Providing the intended application and existing protection details also helps with technical review.

Discuss Your Surge Protection Requirements

Contact TU-SHAN Electric with your project requirements for the TZU5-D. Include the supply voltage, pole configuration, installation location and expected quantity so the product version and available documentation can be reviewed for your application.

Send Inquiry