A Type 1 AC Surge Protection Device is designed for low-voltage AC electrical installations where partial lightning current may enter the power supply system. It is commonly considered for buildings and facilities with an external lightning protection system or other conditions that require Type 1 protection, subject to the installation's lightning risk assessment and applicable electrical standards.
When lightning strikes a building, a nearby structure, or an incoming power line, part of the lightning current can enter the electrical installation through conductive paths. The resulting surge may damage distribution equipment, control systems, and connected electrical loads. A properly selected Type 1 AC SPD provides a controlled path for surge current and helps limit the resulting transient overvoltage.
TU-SHAN Electric manufactures low-voltage electrical protection products, including surge protective devices, SPD backup protectors, and miniature circuit breakers. For Type 1 AC SPD selection, buyers should confirm the system voltage, earthing arrangement, required lightning-current rating, pole configuration, and installation conditions before choosing a model.
Type 1 protection is primarily used where an installation may be exposed to partial lightning current, rather than only the induced surges commonly addressed by Type 2 protection. It is often evaluated at the incoming power supply of buildings with external lightning protection systems and at other locations identified by the project's lightning protection design.
Typical applications include commercial buildings, industrial facilities, electrical distribution rooms, public infrastructure, and selected renewable-energy installations on the AC side. The required protection level depends on the lightning protection design, supply arrangement, exposure conditions, and local electrical regulations.
Type 1 protection is not automatically required in every distribution board. For some installations, Type 2 protection may be appropriate at a downstream distribution point; other installations may need coordinated Type 1 and Type 2 protection at different locations. The final arrangement should follow the electrical design rather than the product category alone.
A Type 1 AC Surge Protection Device is tested for lightning-current discharge using the 10/350 μs current waveform specified by the applicable product standard. During a surge event, the device conducts surge current through its protective path and helps limit the transient voltage appearing across the protected circuit.
The relevant selection parameter is the lightning impulse current, Iimp, usually stated in kA per pole or protection path. A higher rating is not automatically the right choice for every installation; the required value should be determined by the lightning protection design and the device's intended application.
Installation quality also affects protection performance. Short, appropriately routed connections to the conductors and earthing system help reduce additional voltage caused by wiring inductance during a surge. Follow the manufacturer's wiring diagram, terminal requirements, and installation instructions.
Type 1 and Type 2 SPDs are designed for different surge conditions. Type 1 devices handle partial lightning current where lightning-current protection is required. Type 2 devices are commonly used to limit induced lightning surges and switching overvoltages in distribution systems.
A Type 1 AC SPD is therefore selected according to the installation's lightning-current exposure and protection design, not simply because the equipment is important or the building is large. Where downstream equipment also requires lower residual-voltage protection, a coordinated Type 2 SPD may be installed at a suitable downstream point.
If one device is intended to provide both functions, check whether it is specifically rated and documented as a Type 1+Type 2 combined SPD. A Type 1 product should not be assumed to provide every function of a combined device.
In buildings with an external lightning protection system, a Type 1 AC SPD may be installed at the incoming power distribution point when required by the lightning protection design. The selected device must suit the supply configuration and the expected lightning-current exposure.
Factories and industrial facilities may contain extensive power distribution networks, motor loads, control cabinets, and production equipment. A suitable Type 1 SPD can be part of the incoming power protection arrangement where partial lightning current may enter the installation. Additional downstream protection may be needed for sensitive equipment.
Commercial buildings, offices, schools, hospitals, public facilities, and infrastructure projects may require lightning-current protection based on their building protection systems and electrical design. Product selection should account for the incoming supply, grounding arrangement, and the applicable project requirements.
Some solar and other renewable-energy installations require Type 1 protection on an AC distribution side, depending on the lightning protection design. A Type 1 AC SPD is not a substitute for a photovoltaic DC SPD on the solar array circuit. AC and DC protection devices must be selected for their respective circuit voltages and operating conditions.
A Type 1 SPD must be coordinated with the electrical installation's overcurrent protection and prospective short-circuit current. Depending on the SPD design and manufacturer's instructions, a dedicated SPD backup protector (SCB) or another specified protective device may be required.
An SCB is intended for backup protection of compatible SPDs. An MCB provides circuit protection against overloads and short circuits within its rated operating conditions. These devices serve different functions, so an MCB should not automatically be treated as an equivalent replacement for an SCB.
Before installation, check the manufacturer's specified backup protection, maximum permitted upstream fuse or circuit breaker, short-circuit ratings, and wiring diagram. The correct arrangement depends on the selected SPD and the electrical system.
WENZHOU TUSH-AN ELECTRIC CO., LTD. was established in 2018. Its core team has more than 20 years of experience in the low-voltage electrical industry. Under the TU-SHAN Electric brand, the company develops and supplies surge protective devices, SPD backup protectors, and miniature circuit breakers.
The factory's production processes include welding, glue filling, assembly, testing, and final inspection. Its equipment includes automatic welding machines, a glue-filling machine, and testing machines. The factory has more than 10 personnel, including two technical staff members.
The stated overall production capacity is more than 3,000 units per day and approximately 100,000 units per month across the product range. Capacity and lead time for a specific Type 1 AC SPD order depend on model availability, quantity, and any customization requirements.
TU-SHAN Electric serves overseas customers, including buyers in the Middle East and South America. Importers, distributors, electrical contractors, and project purchasers can contact the company to confirm model availability, technical documents, and supply arrangements for their target market.
TU-SHAN Electric supports wholesale supply and OEM options for suitable products. Depending on the model and order scope, options may include logo printing, packaging customization, and agreed product modifications.
The usual MOQ for standard orders is 50 units per model. Logo printing generally starts at 200 units, while housing or circuit modifications generally start at 1,000 units. Final MOQ and feasibility should be confirmed for the selected product.
Indicative lead times are 3–7 days for stock orders of 50–500 units, 7–15 days for orders of 500–5,000 units, and 12–18 days for OEM logo orders. ODM tooling may require approximately 40 days, followed by around 15 days for production. These are estimates and should be reconfirmed against stock, order quantity, and production scheduling.
Shipping arrangements may include FOB Ningbo or Wenzhou, CIF, and other agreed options. When requesting a quotation, provide the AC system voltage, supply configuration, required Iimp rating, pole configuration, quantity, destination country, and any OEM requirements.
It is designed to discharge partial lightning current in installations where Type 1 lightning-current protection is required. Its suitability depends on the installation's lightning protection design and the device's rated impulse current.
It is commonly considered at the incoming power supply or main distribution point of an installation that requires lightning-current protection. The exact location depends on the building's lightning protection system, supply arrangement, and applicable standards.
Iimp is the rated impulse current used to specify the SPD's lightning-current discharge capability under the applicable test waveform, typically 10/350 μs for Type 1 devices. Confirm the rating per pole or protection path and compare it with the project's design requirements.
Not necessarily. Type 1 protection addresses lightning-current conditions at the appropriate installation point. Sensitive downstream equipment may require coordinated Type 2 protection or additional protection stages, depending on the wiring layout and the equipment's withstand voltage.
The required backup protection depends on the SPD's design, short-circuit rating, prospective fault current, and manufacturer's installation instructions. Use the specified SCB or other approved protective device where required.
Do not assume that an AC SPD is suitable for a PV DC circuit. Use a surge protective device with ratings specifically appropriate for the DC system and its operating conditions.
Provide the system voltage, single-phase or three-phase configuration, earthing arrangement, required Iimp rating, pole configuration, installation location, quantity, and destination country. If OEM labeling or packaging is needed, include those requirements so the team can confirm availability, MOQ, and lead time.
If your project requires a Type 1 AC Surge Protection Device for a building main distribution board, industrial power system, or other compatible AC installation, contact TU-SHAN Electric with your system details and required ratings. Our team can help confirm available models, technical documentation, and wholesale or OEM supply options.