3P+NPE Type 2 AC Surge Protection Device
  • 3P+NPE Type 2 AC Surge Protection Device3P+NPE Type 2 AC Surge Protection Device
  • 3P+NPE Type 2 AC Surge Protection Device3P+NPE Type 2 AC Surge Protection Device
  • 3P+NPE Type 2 AC Surge Protection Device3P+NPE Type 2 AC Surge Protection Device
  • 3P+NPE Type 2 AC Surge Protection Device3P+NPE Type 2 AC Surge Protection Device

3P+NPE Type 2 AC Surge Protection Device

The TZU-40 3P+NPE Type 2 AC Surge Protection Device is configured for three-phase 380V distribution systems, with a nominal discharge current (In) of 20kA and a maximum discharge current (Imax) of 40kA. Its four plug-in modules provide a practical setup for industrial and commercial power distribution, while individual thermal disconnection and visual fault indication help identify modules that need attention during inspection.

Three-phase distribution systems supply motors, variable frequency drives, industrial controllers, UPS equipment and other electrical loads that may be exposed to lightning-induced surges and switching transients. The TU-SHAN Electric 3P+NPE Type 2 AC Surge Protection Device is designed for compatible low-voltage AC distribution systems where phase-to-earth and neutral-to-earth surge protection is required.

The TZU-40 configuration combines three L-pole modules and one N-PE module, with a nominal discharge current of 20kA and a maximum discharge current of 40kA under the 8/20μs waveform. Its plug-in construction, individual thermal disconnection and visual fault indicators support inspection and module-level maintenance.

For electrical distributors, panel builders and project contractors, confirming the wiring topology, earthing system and backup protection requirements before ordering helps ensure the selected SPD matches the intended installation.

20kA Nominal discharge current In
40kA Maximum discharge current Imax
≤1.2kV Specified voltage protection level Up
4 Modules Three L-pole modules plus one N-PE module

Product Features

Four-Module Protection Layout

The assembly consists of three TZU-40 L-pole modules and one TZU-40 N-PE module. The specified protection paths are L1-PE, L2-PE, L3-PE and N-PE. Confirm the wiring diagram before installation, as the four-module arrangement is not interchangeable with every three-phase SPD topology.

20kA In and 40kA Imax

The rated discharge-current values help buyers compare surge protection options for distribution boards and industrial cabinets. Final selection should also account for site exposure, upstream protection and the withstand voltage of connected equipment.

Plug-In Modules for Maintenance

The plug-in structure allows a compatible faulty module to be replaced without necessarily removing the complete assembly. Maintenance personnel should isolate the circuit and follow the manufacturer's replacement procedure before servicing.

Individual Thermal Disconnection

Each module is specified with its own thermal disconnection mechanism and visual fault indicator. These features help maintenance staff identify a module requiring inspection. Indicator interpretation should follow the product instructions.

PA66 Flame-Retardant Housing

The specified housing material is PA66 with a UL94 V-0 flame rating. Buyers requiring material declarations or supporting test documents should request the documentation applicable to the ordered model.

35mm DIN-Rail Mounting

The four-module assembly is designed for a standard 35mm DIN rail and has an IP20 protection rating. Install it inside a suitable electrical enclosure rather than exposing the device directly to rain, dust or outdoor conditions.

Technical Specifications

Parameter Specification
Brand TU-SHAN Electric
Model TZU-40 3P+NPE
Product type Type 2 AC surge protective device
Intended system Three-phase 380V AC distribution
Module configuration 3 × TZU-40 L-pole modules + 1 × TZU-40 N-PE module
L-pole continuous operating voltage (Uc) 275V AC per module
N-PE continuous operating voltage (Uc) 255V AC
Nominal discharge current (In) 20kA, 8/20μs
Maximum discharge current (Imax) 40kA, 8/20μs
Voltage protection level (Up) ≤ 1.2kV; protection mode and test conditions require confirmation
Specified protection paths L1-PE, L2-PE, L3-PE and N-PE
Disconnection mechanism Individual thermal disconnection for each module
Status indication Individual visual fault indicators
Housing material PA66, specified UL94 V-0 flame rating
Operating temperature -40°C to +80°C
Mounting 35mm DIN rail
Module width Four modules
Protection degree IP20
Installation location Inside a suitable electrical enclosure
Earthing arrangements TN-S and TN-C-S; TT compatibility must be confirmed against the manufacturer's wiring diagram
Optional accessories Compatible SPD backup protector (SCB) and grounding busbar

Electrical engineers should verify the final circuit topology, applicable standards, protection-mode ratings and earthing-system compatibility against the official datasheet before approving the model for a project.

How the SPD Works in a Distribution System

Normal Power Supply

Under normal operating conditions, the surge protection elements remain in their normal non-conducting state for transient discharge. The SPD stays connected to the designated protection circuit without serving as a replacement for the normal overcurrent protection of the electrical installation.

Transient Surge Response

Lightning-induced surges and switching operations can produce short-duration voltage spikes in AC distribution networks. When a transient reaches the device's operating threshold, the protection elements conduct surge current through their designated paths, helping limit the voltage stress imposed on connected equipment.

In this configuration, the three L-pole modules correspond to the specified phase protection paths, while the N-PE module serves the neutral-to-earth path. Performance depends on correct wiring, earthing conditions, connection lengths and coordination with other protective devices.

Fault Indication and Module Replacement

Surge exposure and component ageing can affect an SPD's service life. If an applicable abnormal thermal condition develops, the module's thermal disconnection mechanism is designed to disconnect the affected module. The visual indicator helps maintenance personnel identify a unit requiring inspection or replacement.

Coordination with Upstream and Downstream Protection

A coordinated installation may include a Type 1 SPD at the incoming supply where required by the lightning protection design, followed by a Type 2 device at a distribution board. Additional protection may be needed close to sensitive electronic equipment. A Type 2 SPD does not automatically replace upstream Type 1 protection or equipment-level protection.

An appropriate SCB or other specified backup protective device should be selected according to the SPD manufacturer's instructions, the prospective short-circuit current and the upstream protection arrangement.

Applications

Industrial Power Distribution Cabinets

Factory distribution systems supply motors, pumps, fans, variable frequency drives and auxiliary machinery. This model can be evaluated for a compatible three-phase AC distribution point where Type 2 surge protection is required.

Commercial Building Distribution Boards

Office buildings, hotels, shopping centers and other commercial facilities use three-phase supplies for HVAC systems, elevators, lighting and auxiliary loads. SPD selection should reflect the building's electrical design, surge exposure and equipment requirements.

Photovoltaic AC Grid-Connection Cabinets

Commercial and industrial PV installations may require surge protection on the AC grid-connection side. This is an AC SPD and must not be substituted for a correctly rated DC SPD on the photovoltaic array or inverter DC input side.

Three-Phase UPS and Data Center Distribution

UPS input circuits and associated distribution equipment in data centers, communication facilities and industrial control rooms may require protection against transient overvoltages. Confirm compatibility with the UPS manufacturer's requirements and the complete installation design.

Industrial Automation and Control Panels

PLCs, variable frequency drives, sensors, meters and other automation equipment depend on stable electrical supply conditions. Where required, this SPD can form part of the three-phase power protection arrangement. Signal and communication interfaces may need separate SPDs selected for their respective circuits.

HVAC, Pump Control and EV Charging Distribution

Central air conditioning systems, pump cabinets and commercial EV charging installations may use three-phase AC distribution. The required SPD type, rating and mounting position should be determined by the equipment specifications, site exposure and applicable electrical regulations.

Installation and Selection Guide

01. Confirm Supply Check nominal voltage, neutral availability and the earthing arrangement.
02. Check Ratings Verify Uc, Up, In and Imax against the installation requirements.
03. Coordinate Protection Confirm the required SCB or other backup protection and short-circuit coordination.
04. Plan Installation Check wiring, protective earthing, enclosure space and maintenance access.

Network and Earthing Compatibility

Before ordering, confirm the nominal supply voltage, phase-to-earth voltage, neutral conductor and earthing arrangement. Although TN-S and TN-C-S are listed as intended arrangements, final suitability must be verified from the manufacturer's official wiring diagram. Do not assume TT compatibility without supporting documentation.

Continuous Operating Voltage and Protection Level

The specified Uc is 275V AC for each L-pole module and 255V AC for the N-PE module. The specified Up is ≤ 1.2kV. Confirm the applicable protection modes and test conditions, and compare the result with the connected equipment's impulse withstand voltage.

Backup Protection, Earthing and Wiring

Determine whether a compatible SCB or another backup protective device is required. The selection must account for the manufacturer's instructions and prospective short-circuit current. Use a suitable protective earth connection and follow the specified conductor sizing, connection lengths and installation requirements.

Enclosure and Maintenance

IP20 is intended for installation inside a suitable electrical enclosure. Outdoor projects require an enclosure with appropriate environmental protection. Maintenance staff should inspect the visual indicators according to the manufacturer's instructions and isolate the circuit before replacing any module.

Manufacturing and Supply Capabilities

WENZHOU TUSH-AN ELECTRIC CO., LTD was established in 2018 and is supported by a team with more than 20 years of experience in low-voltage electrical products. TU-SHAN Electric focuses on surge protective devices (SPD), surge backup protectors (SCB), miniature circuit breakers (MCB) and related distribution protection products.

The factory's reported equipment includes one glue-filling machine, two automatic welding machines and two testing machines. Across its product range, the company reports output of more than 3,000 units per day and approximately 100,000 units per month.

Manufacturing activities include welding, glue filling, assembly, testing and final inspection. The company references GB/T 18802.1 and IEC 61643-11 for relevant products. Buyers should confirm the applicable standard, test report and certification status for the exact model being purchased.

TU-SHAN Electric serves distributors, importers, electrical contractors and engineering customers, particularly in the Middle East and South America. Standard supply, repeat distribution orders and private-label requirements can be discussed according to the selected model and order quantity.

OEM and ODM Options

Customization Stated MOQ Details
Sample orders 1–10 units Samples offered free of charge; freight payable by the customer
Standard models 50 units per model For distributors and regular stock replenishment
Logo printing 200 units Subject to artwork and order confirmation
Housing or circuit modifications 1,000 units Subject to technical feasibility and specification confirmation
Private-label packaging Confirm with sales Available options depend on the agreed order requirements

Logo, model identification, company name and packaging customization can be discussed for private-label supply. Housing or circuit changes require technical review before production. The company states that no additional mold fee is charged for logo, model, company-name or packaging-box customization; confirm the exact scope when requesting a quotation.

ODM options may include chip parameters, socket layout and color, subject to engineering review. Tooling and modified-product lead times depend on the confirmed design and manufacturing requirements.

Production Lead Times

Order Type Stated Lead Time
Stock orders of 50–500 units 3–7 days for dispatch, subject to stock availability
Batch orders of 500–5,000 units 7–15 days
OEM logo-printing orders 12–18 days
ODM tooling or modifications Approximately 40 days for tooling confirmation, followed by 15 days for batch production
Urgent orders Priority production may reduce lead time by approximately 40%, subject to confirmation and additional charges

Actual lead time depends on stock availability, product configuration, customization, order quantity and production scheduling. Confirm the delivery date in the quotation or order confirmation, especially for project-based purchases.

Shipping, Warranty and Technical Support

Export Shipping

Export orders can be arranged under FOB Ningbo, FOB Wenzhou or CIF terms to the agreed destination. Door-to-door air freight may also be available depending on the destination and shipment requirements. Confirm quantities, packaging, shipping terms and required export documents before dispatch.

Two-Year Warranty

TU-SHAN Electric states a two-year product warranty. Free replacement applies to qualifying product failures caused by component quality issues within the warranty period. Damage resulting from unauthorized disassembly, surge events beyond the specified capability, water ingress, corrosion or incorrect installation is excluded under the stated policy.

Technical Consultation

Online technical support is available for product parameters, installation questions and basic surge protection configuration. Project buyers can provide the supply voltage, earthing arrangement, application and relevant technical requirements for evaluation.

The stated response policy is within two hours for domestic inquiries and within 24 hours in writing for overseas inquiries, subject to the company's service arrangements. Datasheets, English product literature, quotations and available test reports can be requested for the selected model.

Frequently Asked Questions

1. What does 3P+NPE Type 2 AC Surge Protection Device mean?

It describes a configuration with three L-pole modules and one N-PE module. The specified protection paths are L1-PE, L2-PE, L3-PE and N-PE. Confirm the actual wiring arrangement against the manufacturer's circuit diagram.

2. Is this SPD suitable for a three-phase 380V AC system?

The TZU-40 3P+NPE is specified for compatible three-phase 380V AC distribution applications. Check the actual phase-to-earth voltage, neutral arrangement, earthing system and official wiring instructions before installation.

3. What do In 20kA and Imax 40kA mean?

In is the nominal discharge current rating, while Imax is the maximum discharge current rating under the specified 8/20μs waveform. Both values should be evaluated alongside the site's surge exposure and protection coordination requirements.

4. Does the Up rating of ≤ 1.2kV apply to every protection path?

The stated Up is ≤ 1.2kV. The protection modes and test conditions covered by this value must be confirmed in the official datasheet before using it for engineering approval.

5. Can this model be used in a TT earthing system?

TT compatibility must be confirmed using the manufacturer's wiring diagram and technical documentation. Do not assume that the device supports every earthing arrangement simply because it is designed for three-phase distribution.

6. Does the SPD require an SCB backup protector?

The requirement depends on the SPD manufacturer's instructions, prospective short-circuit current and applicable installation rules. A compatible SCB may be required for coordinated backup protection.

7. Can the SPD be installed outdoors?

The IP20 rating is intended for installation inside a suitable electrical enclosure. Outdoor installations require an appropriately rated enclosure and a complete assembly suitable for the site's environmental conditions.

8. Can TU-SHAN Electric supply private-label products?

Logo printing, model identification and packaging customization can be discussed. The stated MOQ for logo printing is 200 units, while housing or circuit modifications have a stated MOQ of 1,000 units, subject to technical and order confirmation.

9. What is the standard MOQ?

The stated MOQ for a standard model is 50 units per model. Sample orders of 1–10 units are available under the stated sample policy, with freight payable by the customer.

10. What information is needed for a quotation?

Provide the required quantity, destination country, nominal supply voltage, earthing arrangement, intended application and any project-specific documentation requirements. Include OEM requirements if applicable so the sales team can confirm the specification, availability and delivery schedule.

Request a Quote for the TZU-40 3P+NPE

Contact TU-SHAN Electric for pricing, availability, technical documentation and OEM supply options. To help confirm the correct configuration, include your order quantity, destination market, three-phase network details and application in your inquiry.

For distributor orders and electrical projects, request confirmation of the wiring diagram, Uc and Up ratings, backup protection requirements, applicable standards and delivery schedule before placing the order.

```
Send Inquiry