English
Products
60kA Type 2 Surge Protection Device
  • 60kA Type 2 Surge Protection Device60kA Type 2 Surge Protection Device
  • 60kA Type 2 Surge Protection Device60kA Type 2 Surge Protection Device
  • 60kA Type 2 Surge Protection Device60kA Type 2 Surge Protection Device
  • 60kA Type 2 Surge Protection Device60kA Type 2 Surge Protection Device

60kA Type 2 Surge Protection Device

The TUZHAV TZU2-B 60kA Type 2 Surge Protection Device handles high surge-current demands in low-voltage AC distribution systems, with a nominal discharge current (In) of 60kA and a maximum discharge current (Imax) of 100kA. It is suitable for compatible industrial distribution boards, large commercial facilities and photovoltaic AC systems. Plug-in modules allow replacement when needed, while the visual status indicator and integrated thermal disconnection support routine inspection and maintenance.
Type 2 AC Surge Protection

The TU-SHAN Electric TZU2-B is a high-capacity AC surge protective device designed for distribution systems exposed to induced lightning surges and switching transients. With a stated nominal discharge current of 60kA and maximum discharge current of 100kA, it is intended for projects that require a higher stated Type 2 surge-current rating.

Its MOV-based protection, plug-in modules and visual status indication support practical installation and maintenance in suitable electrical distribution cabinets. Multiple pole configurations are specified, allowing the selected model to be matched to the supply arrangement and earthing system.

For distributors, panel builders and electrical contractors, the 60kA Type 2 Surge Protection Device provides an option to evaluate for compatible AC distribution applications where surge-current capacity, installation space and maintenance access all matter.

TUZHAN Electric TZU2-B high-capacity Type 2 AC surge protection device
60kA Nominal discharge current (In)
100kA Maximum discharge current (Imax)
35mm DIN rail mounting

Designed for High-Capacity AC Distribution

The 60kA Type 2 Surge Protection Device is connected in parallel with the protected circuit. Under normal operating conditions, its metal oxide varistor (MOV) remains in a high-resistance state. When a transient overvoltage occurs, the MOV conducts surge current and limits the voltage reaching downstream equipment.

Its stated In of 60kA and Imax of 100kA, based on an 8/20μs current waveform, distinguish it from the TZU2-80B, which is specified at In 40kA and Imax 80kA. These figures are surge-current ratings under applicable test conditions; they do not replace assessment of the installation's lightning exposure, protection level or coordination requirements.

The device uses plug-in modules, a visual status window and an integrated thermal disconnection mechanism. These features help technicians inspect module condition and maintain the installation in accordance with the manufacturer's instructions.

Technical Specifications

Parameter Specification
Brand TU-SHAN Electric
Model TZU2-B
Product Type Type 2 AC Surge Protection Device
Maximum Continuous Operating Voltage (Uc) Approximately 275V AC; confirm for the selected protection mode
Nominal Discharge Current (In) 60kA (8/20μs)
Maximum Discharge Current (Imax) 100kA (8/20μs)
Voltage Protection Level (Up) ≤1.8kV, subject to confirmation against the applicable product test report
Protection Rating IP20
Module Width 18mm
Module Dimensions 90 × 18 × 66mm; confirm for the selected configuration
Mounting 35mm DIN rail
Module Design Plug-in
Status Indication Visual status window
Disconnection Mechanism Integrated thermal disconnection
Available Pole Configurations 1P, 1P+N, 2P, 3P and 4P; confirm availability for the exact model
Referenced Standards GB 18802.1 and IEC 61643-1; confirm applicable editions and documentation
Before specification: Confirm Uc, Up, dimensions, available pole configurations, applicable standards and certification status against the current datasheet for the exact model. The stated Uc and Up values should not be treated as verified for every pole configuration or protection mode without supporting documentation.

Features for Installation and Maintenance

Higher Stated Surge-Current Ratings

The 60kA nominal and 100kA maximum discharge-current ratings provide a model option for designs requiring a higher stated Type 2 current rating. Selection still depends on the complete protection design and verified product data.

Replaceable Plug-In Modules

Individual modules can be replaced where permitted by the manufacturer's instructions. This can simplify maintenance in distribution boards and control cabinets without removing the complete base assembly.

Visual Status Window

The front indicator helps maintenance personnel check module condition. Follow the product markings and instructions to determine whether inspection or replacement is required.

Integrated Thermal Disconnection

The thermal disconnection mechanism is designed to isolate a protection element under specified fault conditions. Appropriate upstream backup protection may also be required according to the manufacturer's coordination instructions.

Multiple Pole Options

The specified 1P, 1P+N, 2P, 3P and 4P options can accommodate different distribution arrangements. Confirm the wiring diagram, ratings and availability for the selected configuration before ordering.

DIN Rail Installation

The stated 35mm DIN rail mounting and 18mm module width support installation in compatible electrical cabinets. Check the full assembly dimensions, wiring space and access requirements during panel design.

Typical Application Areas

The TZU2-B may be evaluated for suitable AC distribution circuits where its verified ratings and protection modes match the system requirements.

Industrial Distribution Boards

For suitable industrial distribution points supplying machinery, motor drives and workshop equipment.

Commercial Buildings

For coordinated protection in distribution systems serving offices, retail facilities and public buildings.

Solar PV AC Distribution

For compatible AC-side distribution circuits in PV installations. The DC side requires a separately rated DC SPD.

Transport Infrastructure

For suitable distribution circuits serving tunnel equipment, highway monitoring and other infrastructure systems.

Remote Industrial Facilities

For exposed-site AC distribution where the surge protection design calls for a compatible Type 2 SPD.

Communication Equipment Rooms

For compatible AC supplies serving communication power systems and equipment rooms, with downstream coordination where needed.

The device has an IP20 protection rating and is intended for installation inside a suitable electrical enclosure. It is not designed for direct exposure to rain or other outdoor environmental conditions.

Type 2 SPD Coordination and Installation

A Type 2 SPD should be selected as part of a coordinated surge protection system. The correct device and installation position depend on the supply arrangement, lightning protection design and requirements of the connected equipment.

  • Check system voltage and earthing: Verify Uc, the protection modes and the earthing arrangement for the selected configuration.
  • Assess incoming protection: Where protection against partial direct lightning currents is required, consider an appropriately rated Type 1 or Type 1+2 SPD at the suitable supply point.
  • Coordinate downstream protection: Additional SPDs may be needed near sensitive equipment. Select them according to the system design and coordination requirements.
  • Confirm backup protection: Select upstream fuses or circuit breakers according to the manufacturer's instructions and applicable electrical requirements.
  • Use suitable connection wiring: Keep connection conductors appropriately short and size them according to the applicable installation requirements.
  • Verify documentation: Check the wiring diagram, ratings, applicable standard and test documents for the exact model before installation.

A higher discharge-current rating alone does not guarantee a longer service life or make a device suitable for every installation. Final selection should be based on the complete lightning protection design, verified product data and the requirements of the equipment being protected.

TZU2-B vs. TZU2-80B

The primary stated difference between these two models is their discharge-current rating. Buyers should also compare the protection level, operating voltage, pole configuration, dimensions and supporting test documents before choosing a model for a project.

Comparison TZU2-B TZU2-80B
Nominal Discharge Current (In) 60kA 40kA
Maximum Discharge Current (Imax) 100kA 80kA
Selection Consideration For designs requiring a higher stated discharge-current rating, subject to verification For designs where the stated 40kA nominal rating meets the requirements

The TZU2-B is not automatically the better choice for every project. If the TZU2-80B meets the installation requirements, it may be sufficient. Compare the current datasheets and quotations before making a purchase decision.

Manufacturing and OEM Supply

WENZHOU TUSH-AN ELECTRIC CO., LTD was established in 2018 and is supported by a team with more than 20 years of experience in low-voltage electrical products. Its product range includes surge protective devices (SPDs), surge backup protectors (SCBs), miniature circuit breakers (MCBs) and related electrical protection products.

For distributors, panel builders, electrical contractors and project buyers, TU-SHAN Electric can discuss the TZU2-B alongside other compatible models to help match different protection requirements across a project.

Order Item General Terms
Standard MOQ Generally 50 units per model
Sample Orders 1–10 units may be available; freight paid by the customer
OEM Logo Generally from 200 units, subject to confirmation
Housing or Circuit Modification Generally considered from 1,000 units, subject to technical review
Stock Orders 50–500 units may require approximately 3–7 days when stock is available
Batch Orders 500–5,000 units generally require approximately 7–15 days, subject to scheduling
OEM Orders Logo orders generally require approximately 12–18 days
Export Terms FOB Ningbo/Wenzhou, CIF and door-to-door air freight can be discussed

MOQ, stock availability, lead time, customization feasibility and final pricing must be confirmed for the selected model and order quantity. For OEM projects, confirm artwork, packaging details and any technical changes before production.

Product Quality and Documentation

For project approval, buyers should request the documents relevant to the exact TZU2-B model and pole configuration. Depending on availability, these may include a current datasheet, installation instructions, applicable standard references, test reports and qualification documents.

The stated In, Imax, Up, Uc, thermal disconnection function and enclosure rating should be verified against the actual product documentation. References to GB 18802.1 or IEC 61643-1 should not be treated as proof of third-party certification unless the relevant certificates or reports are available and their scope covers the model being purchased.

Where inspection or testing is specified for an order, confirm the inspection scope and the records that can be supplied before placing the purchase order.

Frequently Asked Questions

1. What type of SPD is the 60kA Type 2 Surge Protection Device?

It is specified as a Type 2 AC surge protection device with In 60kA and Imax 100kA, using an 8/20μs current waveform. Confirm its full electrical ratings and applicable documentation for the exact configuration.

2. What is the difference between the TZU2-B and TZU2-80B?

The stated discharge-current ratings differ. The TZU2-B is rated at In 60kA and Imax 100kA, while the TZU2-80B is rated at In 40kA and Imax 80kA. Other ratings and installation requirements should also be compared.

3. Can the TZU2-B replace a Type 1 SPD?

Not automatically. The TZU2-B is specified as a Type 2 SPD. Where the design requires protection against partial direct lightning currents, a suitable Type 1 or Type 1+2 SPD must be selected for the appropriate position.

4. Can it be used in a solar PV installation?

It may be suitable for a compatible AC distribution circuit on the inverter's AC side. The photovoltaic DC side requires a separate SPD specifically rated for the DC circuit voltage and application.

5. Does the device need backup protection?

Appropriate backup protection may be required. Select the fuse or circuit breaker according to the manufacturer's coordination instructions and the applicable installation requirements.

6. What should I do if the status indicator shows a fault?

Check the indicator markings and product instructions. If the module is indicated as failed, isolate the relevant circuit safely and arrange replacement by qualified personnel according to the manufacturer's procedure.

7. What information is needed for a quotation?

Provide the required pole configuration, system voltage, order quantity, destination country, OEM requirements and project documentation needs. These details help confirm the suitable configuration, availability and lead time.

Request a Quote for TZU2-B

Looking for a high-capacity AC SPD for a distribution project? Share your electrical requirements and order details with TU-SHAN Electric so the model configuration and available documentation can be checked before ordering.

Required pole configuration
System voltage and earthing arrangement
Estimated order quantity
Destination country and delivery schedule
OEM logo or packaging requirements
Applicable standards and test documents

Contact our team for a quotation, current availability and technical information for the selected model.

```
Send Inquiry
Contact Info
Send your product requirements, target specifications and order quantities to discuss suitable electrical protection products, quotations and production arrangements with our team.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
RejectAccept