The Type 1+Type 2 Surge Protection Device from TU-SHAN Electric is designed for low-voltage AC distribution systems that require both Type 1 lightning-current protection and Type 2 surge protection. By integrating both protection functions into one device, a combined SPD can simplify equipment layout and reduce installation space compared with separate devices, where the selected model is suitable for the system design.
This type of surge protective device is used in compatible building distribution systems, commercial electrical installations, industrial distribution cabinets, and the AC side of photovoltaic systems. It helps limit transient overvoltages caused by lightning-related surges and electrical switching events, reducing the risk of damage to connected electrical equipment.
TU-SHAN Electric supplies surge protective devices, SPD backup protectors, and miniature circuit breakers for low-voltage electrical protection applications. Buyers can review the available voltage ratings, pole configurations, discharge ratings, and installation requirements with our team before selecting a model for a project or wholesale order.
Type 1 and Type 2 SPDs serve different but complementary functions. Type 1 protection is designed to handle partial lightning current in installations where lightning-current protection is required. Type 2 protection limits transient overvoltages caused by induced lightning surges and switching operations.
A combined Type 1+Type 2 SPD brings these functions together in one device. During a surge event, its internal protection components conduct surge current and limit the transient voltage presented to the protected circuit. After the transient passes, the device returns to its normal operating state according to its design.
The actual protection performance depends on the SPD's design, rated impulse current, voltage protection level, installation wiring, earthing arrangement, and coordination with other protective devices. A combined SPD does not eliminate the need for a complete lightning protection design or guarantee protection against every type of electrical fault.
A combined SPD integrates Type 1 and Type 2 protection functions, which may reduce the number of separate SPD units needed at a suitable installation point. This can simplify cabinet layout and installation planning. Whether it can replace a separate Type 1 and Type 2 arrangement depends on the system design and the device's documented ratings.
Electrical distribution systems can be exposed to lightning-induced surges and transient overvoltages caused by switching operations. A correctly selected Type 1+Type 2 SPD helps divert surge current and limit transient voltage, reducing the risk of damage to downstream electrical equipment.
An integrated protection design can help save installation space compared with separate SPD units. DIN-rail mounting is available on applicable models. Confirm the product dimensions, pole configuration, terminal arrangement, and wiring instructions before planning the cabinet layout.
The appropriate SPD depends on the system voltage, single-phase or three-phase configuration, earthing arrangement, expected surge exposure, and required protection level. TU-SHAN Electric can help buyers review these requirements and confirm suitable model options.
The following table summarizes the specification ranges provided for the Type 1+Type 2 SPD product category. These values are not necessarily available together in one model. Confirm the exact ratings and technical documentation for the selected product before ordering.
For technical selection, also check the rated impulse current (Iimp), nominal discharge current (In), maximum discharge current (Imax), maximum continuous operating voltage (Uc), voltage protection level (Up), short-circuit ratings, and required backup protection. These values have different meanings and should not be treated as interchangeable.
Combined SPDs may be used in compatible main distribution boards and electrical cabinets in residential buildings, offices, retail premises, schools, clinics, and other facilities. The installation position depends on the building's lightning protection arrangements, incoming supply, earthing system, and electrical design.
Industrial electrical systems may supply motors, control cabinets, PLCs, variable frequency drives, instrumentation, and other equipment that can be affected by transient overvoltages. A suitably rated combined SPD can form part of the electrical protection arrangement at an appropriate distribution point.
In a solar installation, a compatible AC SPD may be installed on the inverter's AC output side or at an associated AC distribution point when required by the protection design. A Type 1+Type 2 AC SPD must not be confused with a PV DC SPD. The DC array circuit and AC distribution circuit require devices with ratings appropriate to their respective electrical systems.
Compatible combined SPDs may also be considered for power distribution serving communication rooms, security systems, building automation, and auxiliary electrical equipment. The SPD must be selected for the power circuit it protects; a power SPD is not a substitute for dedicated signal-line protection where that is required.
An SPD, an MCB, and an SCB perform different functions in an electrical protection system. Correct selection and coordination depend on the SPD design, prospective short-circuit current, upstream protective devices, and the manufacturer's installation instructions.
SPD: Limits transient overvoltages and diverts surge current according to its design.
MCB: Provides circuit protection against overloads and short circuits within its specified ratings.
SCB: A dedicated SPD backup protector designed for use with compatible surge protective devices where specified.
A compatible SCB or another specified backup protective device may be required depending on the SPD's short-circuit ratings and installation instructions. An MCB should not automatically be treated as an equivalent replacement for an SCB, and neither device should be selected without checking the manufacturer's coordination requirements.
A Type 1+Type 2 combined SPD can simplify the surge protection arrangement at a suitable point, but it does not mean that every installation can use a single SPD without additional protection. Large buildings, industrial sites, and installations with long cable runs may require coordinated protection at multiple points.
WENZHOU TUSH-AN ELECTRIC CO., LTD. was established in 2018. Its core team has more than 20 years of experience in the low-voltage electrical industry. Under the TU-SHAN Electric brand, the company focuses on surge protective devices, SPD backup protectors, and miniature circuit breakers for electrical protection applications.
The factory's production processes include welding, glue filling, assembly, testing, and final