20kA Type 2 AC Surge Protection Device
  • 20kA Type 2 AC Surge Protection Device20kA Type 2 AC Surge Protection Device
  • 20kA Type 2 AC Surge Protection Device20kA Type 2 AC Surge Protection Device
  • 20kA Type 2 AC Surge Protection Device20kA Type 2 AC Surge Protection Device
  • 20kA Type 2 AC Surge Protection Device20kA Type 2 AC Surge Protection Device
  • 20kA Type 2 AC Surge Protection Device20kA Type 2 AC Surge Protection Device
  • 20kA Type 2 AC Surge Protection Device20kA Type 2 AC Surge Protection Device
  • 20kA Type 2 AC Surge Protection Device20kA Type 2 AC Surge Protection Device
  • 20kA Type 2 AC Surge Protection Device20kA Type 2 AC Surge Protection Device
  • 20kA Type 2 AC Surge Protection Device20kA Type 2 AC Surge Protection Device
  • 20kA Type 2 AC Surge Protection Device20kA Type 2 AC Surge Protection Device
  • 20kA Type 2 AC Surge Protection Device20kA Type 2 AC Surge Protection Device
  • 20kA Type 2 AC Surge Protection Device20kA Type 2 AC Surge Protection Device
  • 20kA Type 2 AC Surge Protection Device20kA Type 2 AC Surge Protection Device
  • 20kA Type 2 AC Surge Protection Device20kA Type 2 AC Surge Protection Device

20kA Type 2 AC Surge Protection Device

The TZU5-C 20kA Type 2 AC Surge Protection Device provides transient overvoltage protection for low-voltage AC distribution systems. It handles a nominal discharge current (In) of 20kA and a maximum discharge current (Imax) of 40kA. Plug-in modules simplify replacement, while the visual status indicator and thermal disconnection mechanism help maintenance personnel check the device condition and identify when attention is needed.

TU-SHANElectric supplies the TZU5-C Type 2 AC surge protection series for low-voltage distribution boards and electrical control cabinets. With a stated 20kA nominal discharge current (In) and 40kA maximum discharge current (Imax), it is designed to help limit transient overvoltages caused by induced lightning and switching operations.

The modular plug-in construction supports module replacement where permitted by the product design. Before ordering, confirm the required pole configuration, supply voltage and earthing arrangement to match the intended installation.

20kA Nominal discharge current
40kA Maximum discharge current
35mm DIN rail mounting

How Surge Protection Works

Connected in parallel with the protected circuit, the 20kA Type 2 AC Surge Protection Device provides a path for surge current when transient overvoltage occurs. This helps limit the voltage imposed on downstream equipment without carrying the normal load current.

01. Normal Voltage

The protection element remains at high impedance during normal operation, allowing the AC circuit to supply its connected loads.

02. Surge Event

During a transient, the protection element conducts surge current to help limit the voltage reaching protected equipment.

03. Thermal Disconnection

The integrated mechanism is designed to disconnect an affected module under specified fault conditions.

04. Status Inspection

The front indicator supports visual checks. Follow the exact model's markings to determine whether replacement is required.

Key Product Features

20kA In and 40kA Imax

The stated discharge ratings use an 8/20μs current waveform. They help engineers compare surge protection models against project requirements and should not be confused with continuous operating current.

Replaceable Plug-In Design

The modular design allows an affected module to be replaced where supported by the product construction. Using the correct replacement module can simplify maintenance and avoid replacing the complete assembly unnecessarily.

Multiple Pole Options

The series information lists 1P, 1P+N, 2P, 3P, 3P+N and 4P configurations. Availability and electrical ratings should be confirmed for the selected version.

Enclosure Installation

The device is designed for 35mm DIN rail mounting and has a stated IP20 rating. Install it inside a compatible enclosure that provides the environmental and touch protection required by the application.

Technical Specifications

Parameter Specification
Brand TU-SHANElectric
Model TZU5-C
Product Type 20kA Type 2 AC Surge Protection Device
Nominal Discharge Current (In) 20kA, 8/20μs
Maximum Discharge Current (Imax) 40kA, 8/20μs
Maximum Continuous Operating Voltage (Uc) Approximately 275V AC in the supplied information; verify each protection mode
Voltage Protection Level (Up) ≤1.2kV in the supplied information; confirm the applicable model rating
Protection Rating IP20
Mounting 35mm DIN rail
Single Module Dimensions (L × W × H) 90 × 18 × 60mm
Overall Dimensions, 4P (L × W × H) 90 × 72 × 60mm
Status Indication Visual status window
Disconnection Mechanism Integrated thermal disconnection
Available Pole Configurations 1P, 1P+N, 2P, 3P, 3P+N and 4P, subject to model availability
Referenced Standards GB 18802.1 and IEC 61643.1 as supplied; applicable editions and test documents require confirmation
Selection note: Confirm Uc, Up, protection topology, pole configuration and earthing arrangement against the exact model's technical datasheet before ordering. The specifications above should not be treated as confirmation that every configuration has identical ratings.

Typical Applications

Commercial and Residential Distribution

For consideration in compatible AC distribution boards serving offices, residential buildings, shopping facilities and other commercial premises.

Industrial Control Cabinets

Can be evaluated for AC supply circuits serving PLCs, sensors, instrumentation and automation equipment. Signal and communication lines may require separate protection devices.

Photovoltaic AC Distribution

May be used on a compatible solar installation's AC side after checking the inverter output and system design. It does not replace a dedicated photovoltaic DC SPD.

Monitoring and Public Facilities

Potential applications include power circuits supplying surveillance equipment, access control, monitoring rooms, schools, hospitals and municipal buildings, subject to the project's protection requirements.

Installation Requirements

Upstream Protection Coordination

Where direct lightning-current exposure is possible, a Type 1 or combined Type 1+2 SPD may be required upstream. Coordinate the protection stages according to the installation design.

Backup Fuse or Circuit Breaker

Follow the manufacturer's requirements for backup overcurrent protection. Confirm the permitted fuse or breaker rating rather than assuming that the existing protective device is suitable.

Wiring and Earthing

Use the designated terminals and wiring diagram. Keep the relevant connecting conductors short and properly routed, and connect protective earth securely to the designated earthing point. Installation should be performed by a qualified electrician in accordance with local regulations.

Quality Documentation

For project procurement, request the applicable datasheet, wiring diagram and available test or compliance documents for the exact TZU5-C configuration. Any claims about surge-current performance, voltage protection level or formal compliance should be supported by records identifying the model and applicable test conditions.

Ordering and OEM Options

TU-SHANElectric supplies low-voltage electrical protection products, including SPDs, SCBs and MCBs. The following are general purchasing terms and should be reconfirmed for the required TZU5-C version.

Item Purchasing Information
Standard MOQ 50 units per model
Samples 1–10 units may be supplied free of charge; customer pays freight
OEM Logo Printing MOQ 200 units
Housing or Circuit Modifications MOQ 1,000 units, subject to technical review
OEM Options Logo, model or company name, and packaging customization
Stock Orders Approximately 3–7 days for 50–500 units, subject to stock confirmation
Batch Orders Approximately 7–15 days for 500–5,000 units
OEM Logo Orders Approximately 12–18 days
Shipping FOB Ningbo or Wenzhou, CIF destination port, or door-to-door air freight, subject to agreement
Warranty 2 years, subject to company warranty terms

Delivery depends on order quantity, stock status, configuration and customization. Internal circuit or housing changes require technical confirmation before acceptance.

Frequently Asked Questions

What is the difference between In and Imax?

In is the nominal discharge current rating, while Imax is the maximum discharge current rating under specified test conditions. Both are surge-current ratings based on the 8/20μs waveform in the supplied specifications.

Can I replace an individual module?

The plug-in design supports module replacement where permitted by the product construction. Use the correct replacement module and follow the manufacturer's maintenance instructions.

Can this model protect a solar DC circuit?

No. An AC SPD must not be substituted for a photovoltaic DC SPD. The 20kA Type 2 AC Surge Protection Device ratings and voltage type must match the circuit being protected.

What information is needed for a quotation?

Provide the pole configuration, AC system voltage, quantity, destination country and any OEM requirements. Project-specific technical specifications can also be submitted for review.

Request Pricing and Availability

Send TU-SHANElectric your required configuration, operating voltage and order quantity to check the applicable model, supply schedule and OEM options.

For quotation: Model configuration · Quantity · Destination country · Packaging or branding requirements

Contact TU-SHANElectric

Send Inquiry
Contact Info
Send your product requirements, target specifications and order quantities to discuss suitable electrical protection products, quotations and production arrangements with our team.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
RejectAccept