The TUZHAV 1P+NPE Type 2 AC Surge Protection Device is designed for single-phase 220V AC distribution systems. With In 20kA, Imax 40kA and Up ≤ 1.2kV, it features plug-in modules, thermal disconnection and visual fault indication.

The TZU-40 1P+NPE Type 2 AC Surge Protection Device is designed for secondary surge protection in compatible single-phase 220V AC distribution systems. With a nominal discharge current of 20kA and a maximum discharge current of 40kA (8/20μs), it helps limit transient overvoltages caused by induced lightning and electrical switching.

The assembly consists of one L-pole module and one N-PE module. The specified continuous operating voltage (Uc) is 275V AC for the L-pole module and 255V AC for the N-PE module, with a stated voltage protection level (Up) of ≤1.2kV. The plug-in design, individual thermal disconnection and visual fault indicators support inspection and module replacement when required.

Designed for 35mm DIN-rail mounting, this AC SPD can be evaluated for residential and commercial distribution boards, security cabinets, communication rooms and industrial control panels. Its IP20 rating requires installation inside a suitable electrical enclosure. Confirm the wiring topology, earthing system, backup protection and applicable ratings before ordering.

TZU-40 1P+NPE Type 2 AC surge protective device front view TZU-40 modular AC surge protector for DIN rail installation

Key Product Features

20kA In and 40kA Imax

The specified nominal discharge current is 20kA, and the maximum discharge current is 40kA under an 8/20μs waveform. These ratings help buyers compare surge-current capacity when selecting a Type 2 SPD for a distribution board or electrical control cabinet.

Separate L-Pole and N-PE Modules

The TZU-40 1P+NPE Type 2 AC Surge Protection Device assembly uses one L-pole module and one N-PE module. The specified Uc values are 275V AC and 255V AC, respectively. Check the official wiring diagram to confirm the internal topology and compatibility with the intended supply and earthing arrangement.

Plug-In Design with Visual Fault Indication

Each module is specified with an individual thermal disconnection mechanism and visual fault indicator. The plug-in construction allows the affected compatible module to be replaced individually, subject to the manufacturer's service instructions and safe isolation procedures.

35mm DIN-Rail Mounting

The two-module configuration is designed for installation on a standard 35mm DIN rail inside a compatible distribution board or control cabinet. The IP20 enclosure rating is intended for protected indoor installation, not direct exposure to rain or outdoor weather.

Technical Specifications

Parameter
Specification
Brand
TU-SHAN Electric
Model
TZU-40 1P+NPE
Product type
Type 2 AC surge protective device
Rated system application
Single-phase 220V AC
Module configuration
1 × L-pole module + 1 × N-PE module
Continuous operating voltage, L-pole (Uc)
275V AC
Continuous operating voltage, N-PE module (Uc)
255V AC
Nominal discharge current (In)
20kA, 8/20μs
Maximum discharge current (Imax)
40kA, 8/20μs
Voltage protection level (Up)
≤1.2kV; verify protection mode and test conditions
Specified protection paths
L-PE and N-PE; confirm against the official wiring diagram
Disconnection mechanism
Individual thermal disconnection for each module
Status indication
Individual visual fault indicators
Housing material
PA66, specified UL94 V-0 flame rating
Operating temperature
-40°C to +80°C
Mounting
35mm DIN rail
Protection degree
IP20
Installation location
Inside a suitable electrical enclosure
Optional accessories
Compatible SPD backup protector (SCB) and grounding busbar, subject to configuration

Final selection should be based on the datasheet and wiring diagram for the exact model. Confirm the declared ratings, applicable protection modes and available test documentation before using the specifications for project approval.

Applications

Residential and Commercial Distribution Boards

The TZU-40 can be evaluated for compatible single-phase distribution boards in houses, apartments, offices, hotels and retail premises. Selection should account for the supply voltage, earthing arrangement, upstream protection and the installation's surge exposure.

Security and Communication Equipment

AC power distribution serving CCTV systems, access control, network equipment and communication rooms may require additional surge protection. This model can be considered for the relevant AC supply circuit; signal and data lines require protection devices selected for their own circuit requirements.

Industrial Control Cabinets

Control panels containing PLCs, instruments, sensors and auxiliary power supplies may need protection against switching transients and induced lightning surges. Confirm that the circuit is compatible with the product's single-phase AC ratings and installation requirements.

EV Charging and Photovoltaic Auxiliary Circuits

The device may be evaluated for compatible single-phase AC auxiliary circuits in EV charging or photovoltaic installations. It is an AC SPD and must not be substituted for a suitably rated DC SPD on a photovoltaic DC circuit.

Selection and Installation Requirements

Check System Voltage and Earthing Arrangement

Confirm the nominal supply voltage and earthing system before selecting the SPD. Compatibility with TN-S, TN-C-S or TT installations must be established from the manufacturer's wiring diagram and the applicable local electrical requirements.

Confirm Backup Protection

Determine whether a compatible SCB or another specified backup protective device is required. Selection depends on the SPD manufacturer's instructions, prospective short-circuit current and coordination with upstream protective devices. An SCB is a backup protection component, not a substitute for the SPD itself.

Allow for Correct Wiring and Enclosure Protection

The installation should follow the specified terminal arrangement, conductor requirements and protective earthing instructions. Because the device is rated IP20, it must be installed inside a suitable enclosure that provides the environmental protection required by the application.

Plan Inspection and Replacement

Check the visual indicators according to the manufacturer's maintenance instructions. If a module indicates a fault, arrange inspection and safe replacement as specified. Do not assume that the remaining module provides complete protection when one module has failed.

Manufacturing and Quality Control

WENZHOU TUSH-AN ELECTRIC CO., LTD was established in 2018. Its team has more than 20 years of experience in low-voltage electrical products and focuses on surge protective devices (SPD), surge backup protectors (SCB), miniature circuit breakers (MCB) and related electrical protection products.

The factory uses glue-filling equipment, two automatic welding machines and two testing machines. Its reported production capacity exceeds 3,000 units per day, or approximately 100,000 units per month across the product range. Production processes include welding, glue filling, assembly, testing and final inspection.

The company serves overseas distributors, importers and engineering customers, particularly in the Middle East and South America. Its relevant product range is developed with reference to standards including GB/T 18802.1 and IEC 61643-11. Applicable standards, test reports and certification status must be verified for the specific model.

OEM and ODM for Distributors and Importers

For buyers developing a private-label SPD range or specifying products for a project, customization can be discussed according to order quantity, electrical requirements and production feasibility.

Service Order requirement Lead time
Standard models MOQ 50 units per model Stock orders of 50–500 units: typically 3–7 days for dispatch
Sample orders 1–10 units; free sample product under the stated policy Confirm stock and dispatch schedule
Logo printing MOQ 200 units Typically 12–18 days
Housing or circuit modifications MOQ 1,000 units Confirm after technical review
ODM tooling and modifications Subject to project confirmation Approximately 40 days for tooling confirmation plus 15 days for batch production

OEM options include logo printing, model identification, company information and customized packaging. Housing or circuit changes require technical evaluation before the specifications, tooling requirements and production schedule can be confirmed. Sample freight is payable by the customer.

Datasheets, English product literature, available test reports and relevant qualification documents can be requested for review. Document availability depends on the selected model and its actual testing or certification status.

Shipping, Warranty and Technical Support

Export Shipping

Available arrangements include FOB Ningbo or Wenzhou, CIF to the agreed destination port and door-to-door air freight, subject to order confirmation and destination. Shipping terms, packaging and delivery schedules should be confirmed in the quotation.

Two-Year Warranty

The stated warranty period is two years for qualifying product failures caused by component quality issues. Damage associated with unauthorized disassembly, incorrect installation, water ingress, corrosion or surge events beyond the product's specified capability is excluded under the stated warranty policy.

Technical Assistance

Buyers can request assistance with parameter confirmation, model selection and surge protection configuration. Providing the supply voltage, earthing arrangement, installation location, required ratings and expected order quantity helps the team evaluate the appropriate model and quotation.

Frequently Asked Questions

What do In 20kA and Imax 40kA mean?

In is the nominal discharge current rating, while Imax is the maximum discharge current rating under the specified 8/20μs waveform. They describe different rated surge-current capabilities and should be compared using the same test basis.

What is the difference between Uc and Up?

Uc is the maximum continuous operating voltage specified for the relevant SPD protection element. Up is the declared voltage protection level under specified test conditions. For this model, the stated Uc values are 275V AC for the L-pole module and 255V AC for the N-PE module, while the stated Up is ≤1.2kV. Confirm the official datasheet for the applicable protection mode.

Can this Type 2 SPD be used in a photovoltaic system?

It may be considered for a compatible single-phase AC auxiliary circuit. The product is not a substitute for a DC SPD on the photovoltaic string or inverter DC input. Select the DC-side protection device according to the system voltage and applicable DC ratings.

Does the TZU-40 require an SCB?

The need for an SCB or another backup protective device depends on the manufacturer's coordination requirements, prospective short-circuit current and upstream protection. Confirm the required backup protection and compatible ratings before installation.

Can the modules be replaced individually?

The plug-in design is intended to allow compatible modules to be replaced individually when required. Follow the manufacturer's instructions, isolate the circuit safely and verify the replacement module's compatibility before servicing.

Is the device suitable for outdoor installation?

The stated IP20 rating is intended for installation inside a suitable electrical enclosure. Direct outdoor exposure is not appropriate. Outdoor use requires an enclosure and complete installation designed for the actual environmental conditions.

What is the MOQ for OEM orders?

The stated MOQ is 200 units for logo printing and 1,000 units for housing or circuit modifications. Standard models have a stated MOQ of 50 units per model. Final quantities, availability and lead times are subject to order confirmation.

What information is needed for a quotation?

Please provide the required quantity, destination country, supply voltage, earthing arrangement, intended application and any project-specific standards or documentation requirements. For OEM orders, also include the required logo, packaging and customization details. This information helps confirm model suitability, available documentation, lead time and quotation terms.

Request a Quote for the TZU-40 1P+NPE

Contact TU-SHAN Electric to request pricing, sample availability, technical documentation or OEM options for the TZU-40 1P+NPE Type 2 AC Surge Protection Device. Send your required quantity, destination, system voltage and application details so that product compatibility and supply terms can be reviewed before ordering.

Send Inquiry
Contact Info
Send your product requirements, target specifications and order quantities to discuss suitable electrical protection products, quotations and production arrangements with our team.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
RejectAccept