30kA Type 2 Surge Protection Device
  • 30kA Type 2 Surge Protection Device30kA Type 2 Surge Protection Device
  • 30kA Type 2 Surge Protection Device30kA Type 2 Surge Protection Device
  • 30kA Type 2 Surge Protection Device30kA Type 2 Surge Protection Device
  • 30kA Type 2 Surge Protection Device30kA Type 2 Surge Protection Device
  • 30kA Type 2 Surge Protection Device30kA Type 2 Surge Protection Device
  • 30kA Type 2 Surge Protection Device30kA Type 2 Surge Protection Device
  • 30kA Type 2 Surge Protection Device30kA Type 2 Surge Protection Device
  • 30kA Type 2 Surge Protection Device30kA Type 2 Surge Protection Device
  • 30kA Type 2 Surge Protection Device30kA Type 2 Surge Protection Device
  • 30kA Type 2 Surge Protection Device30kA Type 2 Surge Protection Device
  • 30kA Type 2 Surge Protection Device30kA Type 2 Surge Protection Device
  • 30kA Type 2 Surge Protection Device30kA Type 2 Surge Protection Device
  • 30kA Type 2 Surge Protection Device30kA Type 2 Surge Protection Device
  • 30kA Type 2 Surge Protection Device30kA Type 2 Surge Protection Device

30kA Type 2 Surge Protection Device

The TZU5-B 30kA Type 2 Surge Protection Device offers a 30kA nominal discharge current (In) and 60kA maximum discharge current (Imax) for low-voltage AC distribution systems. Designed for distribution boards and industrial control cabinets, it uses plug-in modules for convenient replacement, with built-in thermal disconnection and a visual status indicator to help identify when the SPD requires attention.

The 30kA Type 2 Surge Protection Device from TU-SHAN Electric is designed for low-voltage AC distribution systems that require a higher nominal surge discharge rating. With a stated nominal discharge current (In) of 30kA and maximum discharge current (Imax) of 60kA under an 8/20μs waveform, the TZU5-B provides an option for projects where a 20kA-rated model may not meet the specified selection requirements.

Installed in parallel with the protected AC circuit, the device helps divert transient surge current caused by induced lightning and switching operations. It can be evaluated for distribution boards, industrial control cabinets, compatible photovoltaic inverter AC distribution and other low-voltage circuits. The correct version must match the supply voltage, neutral arrangement, earthing system and required protection mode.

30kA Nominal Discharge Current (In)
60kA Maximum Discharge Current (Imax)
35mm Standard DIN Rail Mounting

Technical Specifications

Parameter Specification
Brand TU-SHAN Electric
Model TZU5-B
Product Type Type 2 AC Surge Protective Device
Maximum Continuous Operating Voltage (Uc) Approximately 275V AC; confirm for the selected protection mode
Nominal Discharge Current (In) 30kA, 8/20μs
Maximum Discharge Current (Imax) 60kA, 8/20μs
Voltage Protection Level (Up) ≤1.4kV, subject to confirmation against the exact model documentation
Protection Rating IP20
Mounting Standard 35mm DIN rail
Single Module Width 18mm
Status Indication Visual status window
Disconnection Mechanism Integrated thermal disconnection
Available Pole Configurations 1P, 1P+N, 2P, 3P and 4P; confirm availability for the required version
Referenced Standards GB 18802.1 and IEC 61643 series; confirm the applicable standard edition and product test documentation
Before ordering: Uc, Up, pole configuration and protection topology must be confirmed for the exact model. The values above are based on the supplied product information; request the current datasheet and applicable test documents for project approval.

Designed for Practical Installation and Maintenance

01 / SURGE CAPACITY

30kA In and 60kA Imax

The stated discharge-current ratings give electrical contractors and distributors clear values for initial model comparison. Final selection should also consider Up, site exposure, upstream protection and coordination with other SPDs.

02 / SERVICEABILITY

Replaceable Plug-In Modules

The modular construction allows an affected module to be replaced according to the manufacturer's instructions, without automatically replacing the entire assembly. This can simplify maintenance planning for installations with multiple distribution cabinets.

03 / STATUS CHECK

Visual Status Window

The visual indicator helps maintenance personnel check module status during routine inspections. Follow the product's indicator legend and replacement instructions whenever a fault or end-of-life condition is indicated.

04 / INSTALLATION

35mm DIN Rail Mounting

Standard DIN rail mounting suits compatible low-voltage distribution assemblies. Check the enclosure space, pole arrangement, wiring diagram and required upstream backup protection before installation.

Applications in AC Distribution Systems

The 30kA Type 2 Surge Protection Device can be assessed for compatible AC circuits where transient overvoltage protection is part of the electrical design. The selected voltage rating and pole configuration must match the actual installation.

Industrial Control Cabinets

For compatible distribution circuits supplying PLCs, variable-frequency drives, sensors and industrial control equipment.

PV Inverter AC Side

For suitable AC distribution points associated with photovoltaic inverters. DC-side protection requires a separately selected PV DC SPD.

Communication Equipment

For compatible AC supply circuits serving communication cabinets, base-station auxiliaries and monitoring equipment.

Commercial Buildings

For suitable distribution boards in offices, hotels, retail facilities and other commercial buildings.

Equipment and Network Rooms

For compatible supply circuits serving network cabinets and associated electrical equipment, based on the project's protection plan.

Transport Infrastructure

For appropriately designed AC distribution circuits serving traffic control, monitoring and tunnel auxiliary systems.

How to Select the Correct Version

  • Confirm the AC supply: Provide the nominal system voltage and whether the circuit is single-phase or three-phase.
  • Identify the earthing arrangement: Confirm the neutral and protective-earth configuration before choosing 1P, 1P+N, 2P, 3P or 4P.
  • Check Uc and Up: Match the continuous operating voltage and voltage protection level to the supply system and connected equipment.
  • Plan backup protection: Follow the manufacturer's requirements for the upstream fuse or circuit breaker and check coordination with the installation's prospective short-circuit current.
  • Review the complete protection design: A Type 2 SPD does not automatically replace Type 1 protection where protection against direct lightning current is required.

Ordering from TU-SHAN Electric

Prepare Your Requirements Before Requesting a Quote

TU-SHAN Electric supplies low-voltage electrical protection products for distributors, importers, electrical contractors and project buyers. For a quotation on this model, provide the required quantity, pole configuration, supply voltage, destination country and any OEM requirements.

If the product is intended for a tender or engineering project, include the requested technical standards and documentation. This helps establish which configuration and supporting documents are available before the order is confirmed.

Samples and Minimum Order Quantity

The general standard MOQ is 50 units per model. Between 1 and 10 sample units may be available free of charge, with freight paid by the customer. Confirm sample availability and the terms for the selected model before shipment.

OEM Logo and Customization

Available options may include logo printing, model or company name marking, and customized packaging. The stated MOQ for OEM logo printing is 200 units per model; housing or circuit modifications have a stated MOQ of 1,000 units and require technical review before confirmation.

Production Lead Time and Shipping

For standard stock models, 50–500 units may be dispatched in approximately 3–7 days, subject to stock confirmation. Orders of 500–5,000 units generally require around 7–15 days. OEM logo orders typically require 12–18 days. Actual timing depends on stock, configuration, quantity and customization.

Export terms may include FOB Ningbo or Wenzhou, CIF to the destination port, or door-to-door air freight, subject to order confirmation.

Warranty and Technical Assistance

The company's general warranty period is two years, subject to the applicable warranty terms. Coverage depends on the cause of failure and excludes conditions such as unauthorized disassembly, installation errors and damage outside the product's specified operating capability. Confirm the warranty terms for the exact ordered model.

Technical Documentation and Quality Checks

Before using the product in a project specification, request the current datasheet and the documents applicable to the exact model. Depending on the project, these may include installation instructions, test reports and compliance documentation.

Confirm the stated In, Imax, Up, Uc, pole configuration and applicable standard edition against the product label and technical records. This is particularly important when submitting an SPD for project approval or comparing products from different suppliers.

Looking for a 30kA AC Surge Protection Solution?

Send TU-SHAN Electric your required configuration, order quantity and destination market to check model suitability, current pricing and available technical documentation.

Request a Quotation

Frequently Asked Questions

What is the difference between In 30kA and Imax 60kA?

In is the nominal discharge current rating, while Imax is the maximum discharge current rating under the specified test conditions. Both ratings refer to the stated 8/20μs waveform and do not represent continuous operating current.

How does the TZU5-B compare with the TZU5-C?

Based on the supplied specifications, the TZU5-B is rated at In 30kA and Imax 60kA, while the TZU5-C is rated at In 20kA and Imax 40kA. Compare the voltage protection level, system compatibility and coordination requirements as well as the discharge-current ratings.

Can a Type 2 SPD be used as the only lightning protection device?

Not in every installation. Where the lightning risk assessment or applicable design requires Type 1 protection, a Type 2 SPD should not be treated as a direct substitute. The protection stages should be selected and coordinated for the specific installation.

What should I do if the status indicator shows a fault?

Check the indicator legend and maintenance instructions for the exact model. If the module is shown as faulty or at end of life, arrange inspection and replace it with the correct approved replacement as directed by the manufacturer.

Does this SPD need an upstream fuse or circuit breaker?

Follow the manufacturer's instructions and the applicable electrical design requirements. The appropriate backup protection depends on the SPD specifications, prospective short-circuit conditions and installation configuration.

Can this device protect the DC side of a solar installation?

No. The 30kA Type 2 Surge Protection Device is described as an AC SPD. PV DC circuits require a compatible DC surge protection device selected for the array voltage and DC system configuration.

Which pole configurations can I order?

The supplied series information lists 1P, 1P+N, 2P, 3P and 4P. Confirm the availability, ratings and wiring topology of the required configuration before placing an order.

What information is needed for a quotation?

Provide the required quantity, AC supply voltage, pole configuration, destination country, packaging requirements and any logo or labeling requirements. For project orders, also share the required technical standards and documentation.

```
Send Inquiry