Factory-direct 60kA SPD surge backup protector designed to coordinate with compatible Type 2 SPDs in industrial distribution panels and solar PV AC cabinets. Available in 1P, 1P+N, 2P, 3P and 4P configurations with 35mm DIN rail mounting, visual status indication and optional dry contact remote signaling. Suitable for wholesale distributors, electrical importers and OEM projects, with bulk order pricing and customized configuration quotes available on request.

    Industrial distribution panels and photovoltaic AC systems require coordinated protection to help maintain the safety of electrical equipment and distribution circuits. When a surge protective device (SPD) develops a fault, its backup protection must be able to disconnect the affected branch under the specified operating conditions without interfering unnecessarily with normal surge protection.

    The 60kA SPD Surge Backup Protector for Type 2 Industrial and Solar AC Systems is designed to work with compatible Type 2 SPDs in AC distribution systems. It is suitable for consideration in industrial workshops, factory distribution cabinets, solar PV AC distribution panels, industrial parks and commercial electrical installations.

    With AC 230V/400V system voltage options, multiple pole configurations and 35mm DIN rail mounting, this product can be considered for different low-voltage distribution panel layouts. The appropriate model should be selected according to the connected SPD, system voltage, prospective short-circuit current and required protection coordination.

    Important: This product provides backup protection for a compatible SPD. It does not independently discharge lightning current. Surge protection is performed by the connected SPD.

    60kA SPD Surge Backup Protector for Industrial and Solar AC Distribution60kA Surge Backup Protector Product Structure and Appearance

    Key Features of the 60kA SPD Surge Backup Protector

    Designed for Type 2 SPD coordination

    Provides dedicated backup protection for compatible Type 2 surge protective devices. Its selection should be based on the SPD manufacturer's recommended backup protection and verified coordination requirements.

    Multiple pole configurations

    Available configurations include 1P, 1P+N, 2P, 3P and 4P to accommodate different AC distribution arrangements. The required configuration depends on the electrical system and grounding method.

    35mm DIN rail mounting

    The standard DIN rail mounting format supports installation in compatible industrial and commercial distribution cabinets. Each pole occupies a specified module width of 18mm.

    Optional remote status signaling

    An optional passive dry contact allows the protector's status to be connected to a compatible remote monitoring circuit. Contact ratings and signal logic should be confirmed before integration with SCADA or photovoltaic monitoring systems.

    Operating temperature range

    The specified operating temperature range is -40°C to +85°C, providing an installation option for electrical cabinets operating under different ambient conditions within the product's rated limits.

    How the SPD Backup Protection Works

    Normal Surge Protection

    During a transient overvoltage event, the connected SPD diverts surge current away from the protected equipment. The backup protector is designed to coordinate with the SPD and remain in the required operating state during surge conditions within its verified ratings.

    SPD Fault Disconnection

    If the SPD deteriorates or develops an internal fault, power-frequency follow current may occur depending on its design and the electrical system conditions. The backup protector provides a means of disconnecting the affected SPD branch when the specified operating conditions are reached.

    This arrangement helps isolate a faulty SPD and prevent the affected protection branch from remaining connected to the distribution system. The actual disconnection and breaking performance must be confirmed through the applicable product ratings and coordination documentation.

    Remote Status Monitoring

    For installations requiring centralized equipment monitoring, an optional passive dry contact can provide a status signal to compatible monitoring equipment. This allows the condition of the protection branch to be included in a suitable electrical monitoring arrangement.

    SPD Surge Backup Protector Installation and Connection DetailsSPD Backup Protector Optional Remote Signaling Configuration

    Technical Specifications

    Parameter

    Specification

    Product Name

    60kA SPD Surge Backup Protector

    Intended SPD Application

    Compatible Type 2 SPD

    Rated System Voltage

    AC 230V / 400V

    DC Version

    Optional; separate ratings must be confirmed

    Mounting

    35mm DIN rail

    Pole Options

    1P / 1P+N / 2P / 3P / 4P

    Housing Material

    Flame-retardant PC

    Status Indicator

    Green: normal; red: fault or trip, subject to product marking

    Remote Signaling

    Optional passive dry contact

    Operating Temperature

    -40°C to +85°C

    Protection Rating

    IP20, for cabinet installation

    Single-Pole Dimensions

    18mm W × 80mm H × 66mm D

    Module Width

    1 module per pole

    Standards Reference

    GB/T 33588.3 and applicable IEC 61643 requirements; exact scope and edition to be verified

    Understanding the 60kA rating: The 60kA designation should be interpreted according to the manufacturer's technical documentation, including its applicable current waveform, test conditions and rated performance. It should not automatically be treated as the device's breaking capacity or a universal surge withstand rating.

    DIN Rail Installation and System Compatibility

    The 60kA SPD Surge Backup Protector uses a 35mm DIN rail mounting format for installation in compatible low-voltage distribution cabinets. Its single-pole width is 18mm, with the overall installation space depending on the selected pole arrangement and wiring requirements.

    Available configurations cover several common AC distribution arrangements:

    • 1P: For compatible single-pole protection arrangements.
    • 1P+N: For compatible single-phase AC distribution systems.
    • 2P: For applicable two-pole AC protection arrangements.
    • 3P: For compatible three-phase systems.
    • 4P: For applicable three-phase and neutral protection arrangements.

    Before installation, check the SPD manufacturer's recommended backup protection, rated system voltage, grounding arrangement, prospective short-circuit current and coordination requirements.

    For solar photovoltaic projects, this model is intended for compatible AC distribution circuits. An AC-rated backup protector must not be installed on a DC photovoltaic string or circuit unless its product documentation explicitly confirms suitability. Any optional DC version requires separate verified electrical ratings.

    Typical Industrial and Solar AC Applications

    The product can be considered for low-voltage AC distribution systems where a compatible Type 2 SPD requires dedicated backup protection.

    Industrial workshops and factories: Secondary distribution panels supplying production equipment, control cabinets and auxiliary electrical circuits.

    Solar PV AC distribution cabinets: AC-side distribution systems associated with photovoltaic inverters and related electrical equipment.

    Industrial parks: Distribution cabinets serving production buildings, auxiliary facilities and commercial areas.

    Commercial buildings: Secondary electrical distribution panels in offices, shopping centers, hotels and other commercial facilities.

    Tunnel and infrastructure projects: Auxiliary power distribution cabinets where the electrical design requires coordinated SPD backup protection.

    For each application, the final model selection should be based on the actual circuit configuration and the verified coordination data of the connected SPD.

    Manufacturing and Supply Support from TU-SHAN Electric

    Wenzhou Tush-An Electric Co., Ltd. was established in 2018, backed by a manufacturing team with more than 20 years of experience in low-voltage electrical products. Our product range focuses on surge protective devices (SPD), surge backup protectors (SCB), miniature circuit breakers (MCB) and related low-voltage distribution protection products.

    Our production facility is equipped with one glue filling machine, two automatic welding machines and two testing machines. The current production capacity exceeds 3,000 units per day, with approximately 100,000 units per month.

    These manufacturing resources support regular distributor orders, bulk purchasing and suitable OEM requirements. Production arrangements are coordinated according to product models, order quantities and delivery schedules.

    For buyers evaluating an SPD backup protector, we can assist with model selection, specification confirmation, product documentation and basic application recommendations. Customers can provide their connected SPD model and electrical system details for a more appropriate product evaluation.

    Technical Documentation and Quality Control

    For low-voltage surge protection products, manufacturing consistency and product-specific testing are important considerations when evaluating a supplier.

    Our manufacturing processes include automatic welding, glue filling, assembly and product testing. Relevant surge protection products are manufactured with reference to applicable standards, including GB/T 18802.1 and IEC 61643-11, according to their product scope.

    For this specific backup protector, buyers can request the applicable datasheet and available technical documentation to review its electrical ratings, test conditions, compatibility and installation requirements.

    Type-test reports, certification documents and other third-party records should be confirmed according to the exact model. This helps distributors and project purchasers evaluate the product against their own technical specifications without relying on general statements that may not apply to every model.

    OEM and Bulk Order Support

    For distributors, electrical importers and engineering companies, product consistency and supply arrangements are important when planning repeat purchases.

    TU-SHAN Electric supports discussions regarding suitable OEM branding and packaging requirements for applicable orders. Product configurations, pole arrangements, remote signaling options and technical documentation can be reviewed before order confirmation.

    For quotation and order evaluation, buyers are encouraged to provide the required quantity, system voltage, pole configuration, application and any specific documentation requirements. Sample availability, production lead time, warranty terms and OEM arrangements can then be confirmed for the selected model.

    Frequently Asked Questions

    1. What is the function of an SPD surge backup protector?

    An SPD surge backup protector provides dedicated backup protection for a compatible surge protective device. It is designed to disconnect the affected SPD branch under specified fault conditions. The connected SPD, rather than the backup protector, performs the surge discharge function.

    2. Is this 60kA backup protector compatible with every Type 2 SPD?

    No. Compatibility depends on the SPD's electrical characteristics, recommended backup protection, system voltage, prospective short-circuit current and coordination performance. The 60kA designation alone is not sufficient to establish compatibility.

    3. Can this model be used in solar photovoltaic systems?

    It can be considered for compatible solar PV AC distribution circuits. The selected model must match the AC system parameters and the connected SPD's backup protection requirements. AC and DC versions must not be treated as interchangeable.

    4. What pole configurations are available?

    The specified options include 1P, 1P+N, 2P, 3P and 4P. The appropriate arrangement depends on the electrical system configuration and grounding method.

    5. Does the product support remote monitoring?

    An optional passive dry-contact configuration is specified for compatible remote signaling arrangements. Contact ratings, wiring and signal logic should be confirmed before connection to a monitoring system.

    6. What information should I provide when requesting a quotation?

    Please provide the connected SPD model, rated AC system voltage, required pole configuration, application, estimated order quantity and any OEM or remote signaling requirements. These details help us review the appropriate model and available technical documentation.

    Request a Quotation for Your SPD Backup Protection Project

    Looking for a suitable backup protector for your Type 2 SPD installation? Contact TU-SHAN Electric with your SPD datasheet, AC system voltage, pole configuration and estimated quantity.

    Our team can assist with product specification review, configuration confirmation and quotation preparation for distributor purchases, industrial distribution projects and solar PV AC applications.

    Send Inquiry
    Contact Info
    Send your product requirements, target specifications and order quantities to discuss suitable electrical protection products, quotations and production arrangements with our team.
    X
    We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
    RejectAccept