English
Products
25kA SPD Surge Backup Protector
  • 25kA SPD Surge Backup Protector25kA SPD Surge Backup Protector
  • 25kA SPD Surge Backup Protector25kA SPD Surge Backup Protector
  • 25kA SPD Surge Backup Protector25kA SPD Surge Backup Protector
  • 25kA SPD Surge Backup Protector25kA SPD Surge Backup Protector

25kA SPD Surge Backup Protector

The 25kA SPD Surge Backup Protector is specified as coordinated backup protection for compatible Type 1 SPDs at main incoming distribution level in AC 230V/400V systems. Available in 1P, 1P+N, 2P, 3P and 4P with 18mm single-pole width and 35mm DIN rail mounting, it uses flame-retardant PC housing, green/red status indication and an optional potential-free auxiliary contact for alarm or BMS integration. It does not discharge lightning current itself; suitability depends on verified surge-current coordination, follow-current interruption capability and short-circuit conditions. Send the connected Type 1 SPD model, system voltage, pole configuration and monitoring requirements for a factory quotation and model-specific datasheet.

The 25kA SPD Surge Backup Protector for Type 1 Surge Protection Systems is designed for selected low-voltage power distribution systems serving large commercial buildings, industrial facilities and other installations requiring coordinated lightning protection at the main power entrance.

Type 1 SPDs are used to discharge partial lightning current at suitable points in an electrical installation. Under certain fault conditions, an SPD may deteriorate and develop power-frequency follow current. A compatible backup protector helps disconnect the affected SPD branch when the fault meets the device's operating conditions.

With a modular housing and standard 35mm DIN rail mounting, this device can be incorporated into appropriately designed incoming distribution cabinets. Available in 1P, 1P+N, 2P, 3P and 4P configurations, it supports different circuit arrangements. An optional auxiliary dry contact enables connection to a compatible alarm or building management system, helping maintenance personnel identify a trip condition and arrange inspection.

The backup protector does not independently discharge lightning current or replace the SPD. Its suitability depends on verified surge-current coordination, follow-current interruption capability, system voltage and short-circuit conditions.

25kA class Type 1 duty AC 230/400V operating voltage 1P – 4P pole options 35mm DIN cabinet mounting Dry contact optional signalling

25kA SPD Backup Protector for Type 1 Surge Protection Systems25kA Type 1 SPD Backup Protector Modular Housing

25kA SPD Backup Protector for Type 1 Surge Protection Systems

Role in a Type 1 installation

Type 1 protection sits at the main incoming position, where partial lightning current may enter the installation. In that position the SPD is exposed to high energy stress, and the backup protector is the device that isolates the SPD branch once a qualifying fault develops. It is part of the coordinated protection arrangement, not a substitute for the SPD itself.

What has to be verified before selection

Three inputs decide whether this model is suitable: the connected Type 1 SPD specification and its manufacturer's backup protection recommendation, the system voltage and grounding arrangement, and the prospective short-circuit current at the installation point. The 25kA class designation on its own does not confirm coordination with a specific SPD.

Key Features and Benefits

  1. 01

    Backup Protection for Type 1 SPDs

    Designed for use with compatible Type 1 SPDs in specified 25kA-class applications, the device provides a dedicated disconnection function when the connected SPD develops a qualifying fault. Correct coordination helps manage SPD failure conditions without compromising the intended surge protection arrangement.

  2. 02

    Compact DIN Rail Mounting

    The 35mm DIN rail design supports installation in main distribution cabinets and industrial electrical panels. The single-pole width is 18mm, helping optimize available cabinet space, subject to the selected pole configuration and installation clearances.

  3. 03

    Optional Remote Fault Signaling

    An optional potential-free auxiliary contact can connect to a compatible monitoring or alarm circuit. In large buildings and industrial facilities, this feature can help maintenance teams identify a trip condition without relying exclusively on routine local inspections.

  4. 04

    Multiple Pole Configurations

    Available configurations include 1P, 1P+N, 2P, 3P and 4P. The appropriate configuration should be selected according to the power system, grounding arrangement and protection design.

  5. 05

    AC and DC Options

    The specified AC versions cover 230V and 400V applications. A DC version may be available for selected applications, including photovoltaic systems, subject to confirmation of the required DC voltage, fault interruption capability and compatibility with the associated SPD.

  6. 06

    OEM Branding Support

    OEM product marking and packaging options are available for project and distribution requirements. Samples and technical documentation can be requested for evaluation before confirming a bulk order.

25kA SPD Backup Protector DIN Rail Mounting Details25kA Type 1 SPD Backup Protector Auxiliary Contact Option

For projects that combine Type 1 protection at the incoming position with Type 2 protection downstream, the two backup duties are usually different: this Type 1 model is normally compared with the 40kA SPD Surge Backup Protector used in Type 2 secondary distribution, while higher-energy main distribution designs may require the 80kA or 100kA class. The final decision should follow the Type 1 AC surge protection device manufacturer's coordination guidance rather than the kA figure alone.

Technical Specifications

Item Specification
Product Name 25kA SPD Surge Backup Protector
Intended SPD Type Type 1 SPD; confirm model-specific coordination
SPD Rating Reference 25kA class as specified; verify the applicable current rating and waveform
Rated Operating Voltage AC 230V / 400V
DC Version Optional; confirm model-specific ratings
Available Pole Configurations 1P / 1P+N / 2P / 3P / 4P
Mounting 35mm DIN rail
Single-Pole Dimensions 18mm (W) × 80mm (H) × 66mm (D)
Housing Material Flame-retardant PC, as specified
Status Indication Green for normal status; red for fault/trip status, subject to final product marking
Auxiliary Contact Optional potential-free dry contact
Operating Temperature -40°C to +85°C, as specified
Protection Degree IP20; for installation inside an appropriate enclosure
Referenced Standards GB/T 33588.3 and IEC 61643; applicable parts and conformity to be verified

Typical Applications

The 25kA SPD Surge Backup Protector can be evaluated for the following applications when the product ratings and coordination requirements are suitable:

Large commercial buildingsMain incoming distribution cabinets with coordinated Type 1 surge protection.
Industrial facilitiesIncoming power distribution systems serving factories and production facilities.
Data centersCompatible main power distribution applications where surge protection and fault monitoring are part of the electrical design.
Large photovoltaic installationsDC protection cabinets when a suitable DC-rated version has been confirmed.
Electrical system upgradesExisting distribution cabinets where the installation layout and protection design permit the addition of a compatible backup protector.

Engineering Selection and Coordination

For large power distribution systems, the backup protector must be selected as part of the complete surge protection arrangement. Matching the nominal current designation alone is not sufficient to establish compatibility. Before ordering, confirm the following:

  • SPD model and rating: provide the Type 1 SPD model, rated voltage and relevant surge-current specifications.
  • Power system: identify the AC or DC application, operating voltage and grounding arrangement.
  • Fault conditions: verify the available short-circuit current and required fault-disconnection performance.
  • Surge coordination: confirm that the backup protector is suitable for the SPD's specified surge waveform and current conditions.
  • Pole configuration: select the required 1P, 1P+N, 2P, 3P or 4P arrangement.
  • Monitoring requirements: specify whether an auxiliary dry contact is needed and confirm its contact ratings.
  • Project documentation: identify the applicable standards, test reports, datasheets and OEM marking requirements.

The 25kA SPD Surge Backup Protector for Type 1 Surge Protection Systems should only be approved after its specifications and coordination requirements have been checked against the intended installation. When the panel also houses surge protection devices in a dedicated distribution box, the cabinet layout and rail space should be reviewed together rather than as separate purchases.

Quality Control and Technical Documentation

Documented inspection and testing help establish whether an electrical protection device is suitable for its intended application. For the exact model and production batch, confirm the availability and scope of the following records:

  • Incoming material inspection records
  • Insulation resistance and dielectric withstand test records, where applicable
  • Operating-function and fault-disconnection test results
  • Surge coordination test evidence for the intended Type 1 SPD
  • Applicable environmental and temperature test records
  • Product identification and batch traceability
  • Relevant third-party test reports and technical datasheets

Where third-party reports are required for a project, verify the issuing organization, model identification, tested configuration and applicable standard. A report for one product variant should not automatically be assumed to cover all pole configurations or DC versions.

Frequently Asked Questions

Can this backup protector discharge lightning current independently?

No. It is designed to provide backup protection for a compatible Type 1 SPD. The SPD performs the lightning current discharge function; the backup protector helps disconnect the SPD branch under specified fault conditions.

Can a standard circuit breaker replace a dedicated SPD backup protector?

Not automatically. A standard circuit breaker may have different surge withstand and follow-current interruption characteristics. Replacement suitability must be established using the SPD manufacturer's coordination guidance, the protective device ratings and the applicable installation standards.

Where should the device be installed?

The connection arrangement must follow the manufacturer's wiring diagram and the requirements of the coordinated SPD system. Confirm the actual circuit topology and installation instructions before wiring; a universal series connection arrangement should not be assumed.

What is the benefit of the auxiliary signaling contact in large buildings?

The optional potential-free contact can provide a trip-status signal to a compatible building management or alarm system. This can help maintenance personnel identify a condition requiring inspection. Confirm the contact ratings, terminal arrangement and exact signaling function before integration.

Is a DC version available for photovoltaic systems?

A DC version may be available, subject to confirmation. Before selection, verify the rated DC voltage, polarity arrangement, grounding conditions, fault interruption capability and compatibility with the PV SPD. AC ratings must not be assumed to apply to DC service.

What documentation should be requested for an engineering project?

Request the exact model's datasheet, applicable test reports, relevant standard references and coordination guidance for the intended SPD. Additional documentation should be confirmed against the project's technical specifications and approval requirements.

Are OEM customization and samples available?

OEM marking and packaging options can be discussed according to the required configuration and order specifications. Contact us to confirm sample availability, customization scope, MOQ and lead time.

Request Technical Information

For a large building or industrial power distribution project, share the connected Type 1 SPD model, system voltage, required pole configuration and monitoring requirements. This information helps determine whether the selected backup protector is suitable for the intended installation.

Project evaluation, sample request or distributor pricing?

Send the Type 1 SPD specification, voltage, pole configuration and quantity — our technical team will confirm the matching model and available documentation.

Send Inquiry

Contact us for model-specific specifications, available OEM options, sample arrangements and technical documentation for evaluation.

Send Inquiry
Contact Info
Send your product requirements, target specifications and order quantities to discuss suitable electrical protection products, quotations and production arrangements with our team.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
RejectAccept