The 20kA 3P+NPE Type 2 AC Surge Protector is designed for three-phase AC 380V distribution systems. Its four-module configuration provides L1-PE, L2-PE, L3-PE, and N-PE protection, with In of 10kA, Imax of 20kA, and a specified Up of ≤1.0kV. It supports 35mm DIN rail mounting.
The 20kA 3P+NPE Type 2 AC Surge Protector is designed for compatible three-phase AC distribution systems requiring surge protection on three phase-to-earth paths and the neutral-to-earth path. Its four-module configuration combines three phase protection modules with one dedicated N-PE module.
Rated for a three-phase AC 380V supply system, the TZU-20 has a nominal discharge current (In) of 10kA and a maximum discharge current (Imax) of 20kA, based on the specified 8/20 μs waveform. The stated voltage protection level (Up) is ≤1.0kV under specified test conditions.
The plug-in design allows an individual module to be replaced when required. Each module has a specified thermal disconnection mechanism and visual status indicator, helping maintenance personnel identify modules that require inspection. The device is intended for installation inside a suitable electrical cabinet using a 35mm DIN rail.
Technical Specifications
BrandTUZHAV
ModelTZU-20
Product TypeType 2 AC Surge Protective Device
Configuration3P+NPE, four modules
Rated Supply SystemThree-phase AC 380V
Specified Earthing SystemsTN-S / TN-C-S, subject to wiring compatibility
Phase Protection Modules3 × TZU-20
Phase Module Uc275V AC
Neutral-Earth ModuleTZU-20 N-PE
N-PE Module Uc255V AC
Nominal Discharge Current (In, 8/20 μs)10kA
Maximum Discharge Current (Imax, 8/20 μs)20kA
Voltage Protection Level (Up)≤1.0kV, under specified test conditions
Protection PathsL1-PE, L2-PE, L3-PE, N-PE
Protection ElementMetal oxide varistor (MOV), as specified
Thermal DisconnectionSpecified for each module
Status IndicationVisual fault indicator for each module
Enclosure MaterialPA66, UL94 V-0 as specified
Operating Temperature-40°C to +80°C, as specified
Protection RatingIP20
Mounting35mm DIN rail
Optional AccessoriesCompatible SPD backup protection device (SCB), grounding busbar
Confirm the ratings, wiring configuration and applicable test conditions against the datasheet and test reports for the exact four-module assembly.
Four-Module Configuration and Protection Paths
The TZU-20 3P+NPE configuration contains three phase protection modules and one separate neutral-to-earth module. Each module serves a defined protection path within the compatible distribution system.
Three Phase-to-Earth Protection Paths
The three phase modules are assigned to L1-PE, L2-PE and L3-PE. They are intended to limit transient overvoltages between the respective phase conductors and protective earth according to the device's specified performance.
Separate Neutral-to-Earth Module
The N-PE module addresses transient overvoltages between neutral and protective earth. Its specified continuous operating voltage is 255V AC, compared with 275V AC for each phase module. Correct neutral and PE wiring is essential; the SPD does not replace the required earthing arrangement.
Replaceable Modules for Maintenance
The plug-in construction allows an individual module to be replaced instead of automatically replacing the complete assembly. Each module has its own specified thermal disconnection mechanism and visual status indicator. Follow the product's indicator markings and maintenance instructions, and safely isolate the circuit before removing or replacing a module.
How the TZU-20 Limits Transient Overvoltages
The specified MOV protection elements remain in a high-impedance state during normal operation. When a transient overvoltage occurs, the relevant element conducts and diverts surge current through its intended protection path, limiting the transient voltage according to the device's specified performance.
The actual protection achieved depends on the supply arrangement, earthing system, connection conductor routing, upstream protection and coordination with other SPDs. The stated Up value must be interpreted according to its applicable test conditions and protection mode.
Typical AC Applications
The 20kA 3P+NPE Type 2 AC Surge Protector can be evaluated for compatible three-phase AC distribution circuits in applications such as:
Industrial distribution cabinets: Factory and workshop power distribution, including suitable circuits supplying motor drives and control equipment.
Commercial buildings: Three-phase distribution boards in offices, shopping centres and other commercial facilities.
UPS and electrical infrastructure: Compatible AC supply circuits serving three-phase UPS equipment and associated distribution systems.
Photovoltaic installations: Suitable three-phase AC auxiliary or distribution circuits in commercial and industrial solar installations.
Motor control and HVAC: Compatible supply circuits for pumps, air-conditioning equipment, PLC cabinets and variable-frequency drives.
EV charging infrastructure: Suitable three-phase AC distribution circuits, subject to the installation design and charging equipment requirements.
Important: The TZU-20 is an AC surge protective device. It must not be used on PV DC strings or battery circuits unless a separate product is specifically rated for those circuits. Confirm compatibility with the actual supply voltage, earthing system and equipment manufacturer's requirements before selection.
Coordination with Upstream Protection
The TZU-20 is a Type 2 SPD for use within a coordinated surge protection system. Depending on the lightning risk assessment and installation design, the system may also require Type 1 protection at the incoming supply and additional protection for downstream equipment or signal circuits.
A Type 2 SPD does not replace a required Type 1 device. Coordination between protection stages must follow the applicable standards and manufacturers' instructions. A compatible SPD backup protection device, such as an SCB, may also be required according to the SPD documentation and installation conditions.
Select the backup protection according to the specified ratings, the SPD manufacturer's requirements and the prospective short-circuit current. Proper protective-earth connections and appropriately routed conductors are also essential to the overall installation.
Installation and Maintenance
The TZU-20 uses 35mm DIN rail mounting and has a specified IP20 protection rating. It is intended for installation inside a suitable electrical cabinet rather than direct exposure to rain or outdoor conditions. Outdoor installations require an enclosure with appropriate ingress protection and environmental suitability.
Before installation, verify the supply voltage, earthing arrangement, phase and neutral connections, backup protection requirements and coordination with other SPDs. The supplied product information specifies TN-S and TN-C-S systems. Compatibility with TT systems must be confirmed with the manufacturer; it should not be assumed from the Uc ratings alone.
During maintenance, check the status indicators according to the product markings. If a module indicates failure, arrange safe isolation and follow the specified replacement procedure. Do not rely on a failed module for surge protection.
Technical Documents and Quality Verification
For project evaluation, confirm the available datasheet, wiring diagram, applicable standard editions, test reports and compliance documentation for the exact TZU-20 3P+NPE assembly. Any performance or compliance claims should correspond to the relevant product records and test conditions.
For technical confirmation, provide the intended application, supply voltage, earthing system and required protection configuration. These details help establish whether the specified four-module assembly is suitable for the installation.
Frequently Asked Questions
Is the TZU-20 3P+NPE a Type 1 or Type 2 SPD?
It is specified as a Type 2 AC surge protective device for compatible three-phase distribution systems. Where Type 1 protection is required at the incoming supply, a suitable upstream Type 1 SPD must be considered.
What do In 10kA and Imax 20kA mean?
In is the nominal discharge current rating, while Imax is the maximum discharge current rating under the specified 8/20 μs test conditions. They are different ratings and should be compared using the applicable product test standard.
Why are the phase and N-PE modules rated at different Uc values?
The phase modules and N-PE module serve different electrical paths and have different specified continuous operating voltages: 275V AC for the phase modules and 255V AC for the N-PE module. Confirm the wiring arrangement and system compatibility against the manufacturer's documentation.
Can the 20kA 3P+NPE Type 2 AC Surge Protector be used in a TT earthing system?
The supplied product information specifies TN-S and TN-C-S systems. TT compatibility must be confirmed with the manufacturer, including the N-PE arrangement, wiring requirements and backup protection.
Does the TZU-20 require an SCB backup protection device?
The requirement depends on the manufacturer's instructions, short-circuit conditions and installation design. Confirm the compatible backup protection type and ratings before installation.
Can the modules be replaced individually?
The plug-in structure allows individual module replacement when required. The circuit must be safely isolated, and replacement must follow the product's wiring and maintenance instructions.
Can this AC SPD be installed on a solar DC circuit?
No. The TZU-20 described here is an AC SPD. PV DC strings and battery circuits require surge protection devices specifically rated for the relevant DC voltage and circuit configuration.
Can the TZU-20 be installed outdoors?
Its specified IP20 rating is intended for installation inside a suitable enclosure. Outdoor use requires an enclosure with appropriate ingress protection and environmental suitability.
What information is needed to confirm product suitability?
Provide the supply voltage, earthing system, intended application and required protection configuration. The relevant datasheet, wiring diagram and test documentation should then be checked against the actual installation requirements.
Technical Enquiries
Contact TUZHAV Electric with your system voltage, earthing arrangement and application details to confirm the TZU-20 3P+NPE configuration and the relevant technical documentation for your project.
Send your product requirements, target specifications and order quantities to discuss suitable electrical protection products, quotations and production arrangements with our team.
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy