The TUZHAN Electric TZU-40 3P is a Type 2 DC surge protective device designed for compatible 500VDC photovoltaic systems. It helps limit transient overvoltages caused by lightning-induced surges and switching events, reducing the risk of surge-related damage to inverter inputs and other connected DC equipment.
Its plug-in module construction supports replacement when required. Built-in thermal disconnection and visual status indication make routine inspection more straightforward for installers and maintenance teams.
Designed for installation in suitable PV combiner boxes, inverter cabinets and electrical enclosures, this device provides a practical option for solar system integrators, electrical wholesalers and project contractors selecting DC-side surge protection.
| Parameter | Specification |
|---|---|
| Brand | TUZHAN Electric |
| Product Model | TZU-40 3P |
| Product Type | Type 2 DC Surge Protection Device |
| Application | Photovoltaic DC surge protection |
| Rated System Voltage | 500VDC |
| Maximum Continuous Operating Voltage (Uc) | 500VDC |
| Nominal Discharge Current (In) | 20kA (8/20 μs) |
| Maximum Discharge Current (Imax) | 40kA (8/20 μs) |
| Voltage Protection Level (Up) | ≤ 2.1kV |
| Pole Configuration | 3P |
| Protection Paths | DC+ to PE and DC− to PE, subject to the confirmed wiring diagram |
| Connection Type | Plug-in modules |
| Mounting Method | 35mm DIN rail |
| Disconnection Protection | Built-in thermal disconnect |
| Status Indication | Visual status indicator |
| Housing Material | Flame-retardant PA66 |
| Flammability Rating | UL94 V-0 |
| Protection Degree | IP20 |
| Operating Temperature | -40°C to +85°C |
Designed for compatible 500VDC photovoltaic circuits, the device helps limit transient overvoltages on the DC side before they reach connected equipment. Confirm that the voltage rating and protection level match the PV system and the equipment being protected.
The specified In of 20kA and Imax of 40kA use an 8/20 μs current waveform. These ratings help system designers assess surge-current capability alongside installation location, expected surge exposure and coordination with other protective devices.
The plug-in design allows modules to be removed and replaced when necessary. This can simplify maintenance without requiring replacement of the complete assembly, subject to the manufacturer's replacement procedure and the availability of compatible modules.
The built-in thermal disconnect is designed to disconnect a protection element under specified abnormal thermal conditions. The visual indicator helps maintenance personnel check the module's indicated status during inspection.
The housing material is specified as flame-retardant PA66 with a UL94 V-0 rating. The device operates within the stated -40°C to +85°C temperature range, subject to the applicable product specifications.
The 35mm DIN rail mounting format supports installation in appropriately designed electrical cabinets and enclosures. Allow sufficient space for wiring, inspection and module replacement according to the installation instructions.
Installation condition: IP20 is intended for protected installation conditions. Install the SPD inside a suitable enclosure and select enclosure protection according to the site's exposure to moisture, dust, corrosion and weather.
The 500V DC Type 2 Solar Surge Protection Device 3P is intended for compatible photovoltaic DC circuits where its voltage rating, wiring arrangement and protection characteristics meet the project requirements.
DC-side surge protection for suitable commercial and industrial photovoltaic distribution systems.
Protection at designated DC-side locations in compatible inverter installations.
For suitable DC circuits in solar tracking control equipment.
For compatible DC distribution circuits in off-grid photovoltaic installations.
For suitable PV electrical equipment used in solar-powered agricultural installations.
DC-side surge protection where system voltage and circuit design match the device ratings.
For energy-storage or other DC applications, confirm the operating voltage, circuit topology, grounding arrangement and fault-current conditions before selecting the device. A photovoltaic SPD should not be assumed suitable for every DC circuit.
Quality checks for this product range cover incoming material inspection, production checks and electrical testing. The stated procedures include the following areas:
MOV components and other incoming materials are subject to sampling inspection against relevant production requirements before use.
Surge and temperature ageing tests are used to evaluate protection components under specified test conditions. The applicable test methods and acceptance criteria should be confirmed from the technical documentation for the ordered model.
Batch inspection checks the intended thermal disconnection function under the applicable test conditions.
Stated final inspection procedures include DC withstand testing, residual voltage testing and checks of the visual status indication. Flame-retardancy and thermal-ageing checks are also included in the described quality-control procedures.
The supplied product information references GB/T 33588 in relation to standards and testing documentation. Confirm the exact applicable standard, test scope and availability of any third-party laboratory report for the specific model before procurement.
The specified Uc is 500VDC. Before selection, calculate the PV array's maximum open-circuit voltage under the lowest expected operating temperature and verify that it remains within the permitted limits of the selected SPD and the system design. Do not select an SPD using nominal system voltage alone.
Typical installation locations include suitable PV combiner boxes and inverter cabinets. The final position should account for cable length, system layout, lightning protection design and coordination with other SPDs in the installation.
Connect DC+, DC− and PE according to the manufacturer's wiring diagram. The PE terminal must be integrated into the system's protective earthing arrangement. Because the product is identified as a 3P configuration, confirm the actual terminal layout and module arrangement before installation.
Where backup protection is required, select the compatible surge backup protector or other specified overcurrent protection based on the manufacturer's coordination requirements, prospective short-circuit current and fault conditions. The SPD and backup device should be evaluated as a coordinated combination.
Isolate the relevant circuit and follow the manufacturer's instructions before inspecting or replacing a module. If the visual indicator shows a fault condition, do not assume that the affected module continues to provide its specified protection.
No. The TZU-40 3P described here is a Type 2 DC SPD for compatible 500VDC photovoltaic circuits. AC applications require a surge protective device with the correct AC voltage rating and circuit configuration.
In is the nominal discharge current, while Imax is the maximum discharge current. Both values are specified using an 8/20 μs current waveform. They represent different surge-current ratings and should not be treated as interchangeable.
Check the array's maximum open-circuit voltage under the lowest expected temperature, then compare it with the SPD's rated limits. The system designer should also verify the protection level and compatibility with the connected equipment.
The product is described as having a plug-in module design. Replacement should follow the manufacturer's procedure, use compatible modules and be performed only after the relevant circuit has been safely isolated.
Yes. Its stated protection degree is IP20, so it should be installed inside a suitable electrical enclosure. Outdoor installations need an enclosure selected for the actual environmental conditions.
It may be suitable for selected DC circuits if the voltage, topology, grounding arrangement and protection requirements match the product specifications. Confirm compatibility with the technical team before ordering.
That depends on the installation requirements, prospective short-circuit current and the manufacturer's coordination guidance. Confirm the correct backup protection and ratings for the specific system.
Yes. Ask TUZHAN Electric to confirm the model-specific datasheet, wiring diagram and available test documentation. Any third-party report or compliance document should be checked for its model reference and test scope.
WENZHOU TUSH-AN ELECTRIC CO., LTD was established in 2018. The team has more than 20 years of experience in low-voltage electrical products and focuses on surge protective devices (SPD), surge backup protectors (SCB) and miniature circuit breakers (MCB).
Manufacturing processes include welding, assembly, glue filling, testing and final inspection. The company has dedicated SPD automated assembly lines and production capacity for different SPD product types, supporting orders for distributors, importers and electrical project suppliers.
For purchasing enquiries, customers can discuss model selection, samples, standard orders, logo customization and project-specific requirements with the sales team. Confirm stock, MOQ, lead time, wiring configuration and documentation for the exact model before placing an order.
Contact TUZHAN Electric to confirm the 500VDC model, wiring configuration, available technical documents and order requirements for your application.
Share your system voltage, application and estimated quantity to help the team assess the suitable configuration.
Address
No.51, Changjiang Road, Wenzhou Bridge Industrial Zone, Beibaixiang Town, Yueqing City, Zhejiang Province, China
Tel
