The 1000V DC Type 2 Solar Surge Protection Device 2P from TUZHAN Electric is designed for secondary surge protection in compatible 1000VDC photovoltaic systems. It helps limit transient overvoltages caused by induced lightning surges and switching events, reducing the risk of damage to solar inverter inputs and other DC-side equipment.
Built around two TZU-40 DC protection modules, the device provides separate protection paths from DC+ to PE and DC− to PE. Each module features an independent thermal disconnection mechanism and visual fault indicator, helping maintenance teams identify the affected module during inspection.
For solar equipment manufacturers, PV installers and electrical distributors, the plug-in module construction, standard 35mm DIN-rail mounting and flame-retardant PA66 housing make this model practical for integration into suitable combiner boxes and DC distribution cabinets.
Use the following specifications to check compatibility with your PV system, enclosure and surge protection design before ordering.
| Parameter | Specification |
|---|---|
| Brand | TUZHAN Electric |
| Model | TZU-40 2P 1000VDC |
| Product Type | Type 2 Solar DC Surge Protective Device (SPD) |
| Application | Compatible 1000VDC photovoltaic systems |
| Module Configuration | 2 × TZU-40 DC modules |
| Maximum Continuous Operating Voltage (Uc) | 1000VDC |
| Nominal Discharge Current (In) | 20kA (8/20μs) |
| Maximum Discharge Current (Imax) | 40kA (8/20μs) |
| Voltage Protection Level (Up) | ≤3.4kV |
| Protection Paths | DC+ to PE; DC− to PE |
| Thermal Disconnection | Independent mechanism for each module |
| Status Indication | Visual fault indicator on each module |
| Housing Material | Flame-retardant PA66 |
| Flammability Rating | UL94 V-0 |
| Operating Temperature | -40°C to +80°C |
| Mounting | 35mm DIN rail |
| Protection Degree | IP20 |
| Installation Location | Inside a suitable electrical enclosure |
| Optional Accessories | DC surge backup protector (SCB), grounding copper bar |
The TZU-40 2P uses metal oxide varistor (MOV) technology to respond to transient overvoltages. During normal operation, the MOV elements remain at high impedance and carry only a small leakage current. When a surge occurs, they conduct surge current through the designated protection paths to help limit the voltage reaching connected equipment.
The two modules are arranged to protect the positive and negative DC conductors relative to protective earth. Correct connection depends on the system grounding configuration and the product wiring diagram. This is particularly important when integrating the SPD into an existing PV combiner box or inverter DC compartment.
Repeated surge exposure and component ageing can affect MOV performance. Each module has its own thermal disconnection mechanism, allowing the affected protection element to be disconnected when the specified operating conditions are reached. The visual indicator supports inspection and maintenance, but does not replace scheduled checks or electrical testing.
The plug-in construction supports individual module replacement when permitted by the manufacturer's instructions. This can simplify service work and spare-parts management compared with replacing the complete assembly. Always isolate the circuit and verify it is de-energized before carrying out maintenance.
Provides secondary surge protection at a designated DC protection point in compatible residential, commercial or industrial photovoltaic installations.
Helps limit transient overvoltages entering inverter-side DC circuits when installed and coordinated according to the system protection design.
Suitable for protected installation in compatible 1000VDC distribution cabinets with adequate wiring space and enclosure protection.
May be considered for other DC applications only after confirming voltage rating, grounding arrangement, fault conditions and the manufacturer's specified use.
The 1000VDC Uc rating must be assessed against the PV array's maximum open-circuit voltage, including the increase in string voltage at the lowest expected operating temperature. Do not select an SPD based only on the nominal system voltage.
The specified Up is ≤3.4kV. Confirm that this protection level is appropriate for the withstand voltage of the inverter and other protected equipment. Cable lengths, grounding arrangements and coordination with upstream or downstream SPDs can affect the protection achieved at the equipment terminals.
Type 2 protection is intended for secondary surge protection. Depending on lightning exposure, the building's external lightning protection system and project requirements, Type 1 or Type 1+2 protection may also be necessary. Select coordinated devices according to the applicable installation design rather than treating different SPD types as interchangeable.
A compatible DC surge backup protector (SCB) may be required by the manufacturer's instructions or the project's fault-current conditions. Check the recommended backup device, prospective short-circuit current and coordination requirements. Do not select the SCB solely by nominal current.
The IP20 device is intended for protected installation, not direct exposure to rain or dust. For outdoor photovoltaic equipment, select an enclosure suitable for the site's moisture, dust, temperature and corrosion conditions, and ensure that the installation meets applicable electrical requirements.
TUZHAN Electric's stated inspection process for this product covers key components, protective functions and finished-product checks. For procurement teams, confirming the applicable inspection records and technical documents before order placement helps establish clear acceptance requirements.
Incoming MOV components are sampled for inspection. The stated checks include 8/20μs surge-current testing and high- and low-temperature ageing checks before components proceed to production.
Production-batch samples undergo thermal disconnection testing to check the operation of the safety mechanism under the applicable test conditions.
The stated final inspection includes DC withstand testing, residual voltage testing and visual status indication checks. Confirm the exact test scope and acceptance criteria for the specific model when technical records are required for a project.
Production, testing, inspection and shipment records are maintained by batch to support product traceability. Available test reports and technical documents can be confirmed during quotation and order review; certification or report availability should be verified for the specific model rather than assumed.
| Feature | Practical Value |
|---|---|
| Type 2 DC protection | Designed for secondary surge protection in compatible PV DC circuits. |
| Uc 1000VDC | For compatible 1000VDC systems after maximum array voltage verification. |
| In 20kA / Imax 40kA | Provides stated nominal and maximum discharge current ratings using an 8/20μs waveform. |
| Up ≤3.4kV | Allows engineers to assess the specified voltage protection level against equipment requirements. |
| Two plug-in modules | Separate DC+ to PE and DC− to PE protection paths. |
| Independent thermal disconnection | Each module has its own disconnection mechanism. |
| Visual fault indicators | Helps maintenance staff identify a module requiring inspection. |
| 35mm DIN-rail mounting | Compatible with standard DIN-rail installation where enclosure space permits. |
| IP20 housing | Requires installation inside a suitable electrical enclosure. |
2P refers to the two-module configuration, with separate protection paths for DC+ to PE and DC− to PE. Follow the wiring diagram and verify compatibility with the system grounding arrangement.
No. The TZU-40 2P is designed for compatible DC applications. An AC installation requires an SPD specifically rated and configured for the relevant AC system.
In is the nominal discharge current rating, while Imax is the maximum discharge current rating. Both values are specified using an 8/20μs waveform and represent different test ratings.
This model is specified for compatible 1000VDC applications. Do not use it in a 1500VDC system unless the full product ratings and system design explicitly support that application. A suitably rated SPD should be selected for a 1500VDC array.
The plug-in construction supports individual module replacement. Confirm the correct replacement module and follow the manufacturer's maintenance procedure. Isolate the circuit and verify it is de-energized before servicing.
No. The IP20 rating requires installation inside a suitable electrical enclosure. The enclosure must provide environmental protection appropriate to the installation site.
The requirement depends on the manufacturer's coordination instructions, prospective short-circuit current and system design. Confirm the recommended backup protection and its ratings before ordering or installation.
Provide the quantity, destination country, PV system voltage, installation location, required delivery schedule and any OEM requirements. If your project requires specific test reports or technical documents, list them in the inquiry so their availability can be checked before order confirmation.
WENZHOU TUSH-AN ELECTRIC CO., LTD was established in 2018. Its team has more than 20 years of experience in low-voltage electrical products and focuses on surge protective devices (SPD), surge backup protectors (SCB), miniature circuit breakers (MCB) and related electrical protection products.
The factory operates two dedicated SPD automatic assembly lines and two production lines for socket-type terminal surge protection products. Equipment includes a glue filling machine, automatic welding machines and testing equipment. The stated monthly capacity across the SPD product range is approximately 100,000 units, while socket-type Type III SPDs have a stated daily capacity of 5,000 units.
TUZHAN Electric serves overseas markets, particularly the Middle East and South America. Standard products may be available from stock, subject to current inventory. The company also supports OEM and ODM cooperation for customers developing their own brands or adapting products to project requirements.
| Order Type | MOQ | Details |
|---|---|---|
| Sample order | 1–10 pcs | Free samples may be available for qualifying requests; freight is collected. |
| Standard product | 50 pcs per model | Standard MOQ for regular orders. |
| OEM logo printing | 200 pcs | Customer logo and marking customization. |
| Housing or circuit modification | 1,000 pcs | Subject to technical evaluation and confirmation. |
| Distributor orders | Negotiable | Mixed models and consolidated shipments can be discussed. |
Sample availability, final MOQ and freight arrangements should be confirmed with the sales team before ordering.
Branding and packaging: Customer logo printing, product marking and customized color packaging are available. Under the stated service arrangement, standard logo and packaging customization does not require an additional tooling fee.
Product modifications: Selected projects may involve changes to internal protection component parameters, socket layout, housing appearance or color. Technical feasibility, samples and final specifications must be confirmed before production.
Export documentation: English product materials, manuals and available test reports or qualification documents can be discussed according to the model and order requirements.
| Order Type | Stated Lead Time |
|---|---|
| Stock order, approximately 50–500 pcs | 3–7 days for dispatch |
| Regular bulk order, approximately 500–5,000 pcs | 7–15 days for production |
| OEM logo-printing order | 12–18 days |
| ODM tooling or modification project | Approximately 40 days for tooling confirmation, plus 15 days for batch production |
| Urgent order | Priority scheduling may be available after confirmation, with an additional rush fee where applicable. |
Actual lead time depends on inventory, order quantity, customization requirements and the production schedule. Confirm the dispatch date before placing an order.
Available arrangements include FOB Ningbo or Wenzhou, CIF destination port, air freight and door-to-door shipping, subject to destination, shipment size and agreed trade terms.
The stated warranty is two years for qualifying component quality failures, subject to the applicable warranty terms. Unauthorized disassembly, incorrect installation, water ingress, corrosion and surge events exceeding the product's specified ratings may be excluded.
TUZHAN Electric provides online technical consultation and assistance with surge protection scheme design. The stated response targets are within two hours for domestic inquiries and within 24 hours for overseas written inquiries, taking time-zone differences into account.
Contact TUZHAN Electric for current pricing, availability, technical confirmation and OEM options. Share your application details so the product configuration and order conditions can be checked before purchasing.
Include the following in your inquiry:
Required quantity, destination country, PV system voltage, installation location, standard or OEM requirements, target delivery date and required technical documents.
Our team can confirm the applicable specifications, available documentation, MOQ, production lead time and shipping arrangements for your order.
Contact TUZHAN ElectricAddress
No.51, Changjiang Road, Wenzhou Bridge Industrial Zone, Beibaixiang Town, Yueqing City, Zhejiang Province, China
Tel