English
Products
1000V DC Type 2 Solar Surge Protection Device 3P
  • 1000V DC Type 2 Solar Surge Protection Device 3P1000V DC Type 2 Solar Surge Protection Device 3P
  • 1000V DC Type 2 Solar Surge Protection Device 3P1000V DC Type 2 Solar Surge Protection Device 3P
  • 1000V DC Type 2 Solar Surge Protection Device 3P1000V DC Type 2 Solar Surge Protection Device 3P
  • 1000V DC Type 2 Solar Surge Protection Device 3P1000V DC Type 2 Solar Surge Protection Device 3P

1000V DC Type 2 Solar Surge Protection Device 3P

The 1000V DC Type 2 Solar Surge Protection Device 3P is designed for photovoltaic DC systems. It features MOV technology, a 20kA nominal discharge current, a 40kA maximum discharge current, plug-in modules, thermal disconnection, and visual fault indicators.

TUZHAN ELECTRIC · SOLAR DC PROTECTION

1000V DC Surge Protection for Solar Power Systems

The 1000V DC Type 2 Solar Surge Protection Device 3P is designed for photovoltaic DC circuits that require protection against transient overvoltage. With a plug-in structure and visual status indication, it supports installation and maintenance in solar combiner boxes, inverter DC circuits, and PV electrical cabinets.

TUZHAN Electric supplies standard products and supports OEM and ODM requirements for electrical protection projects. Contact us with your system voltage, circuit configuration, and required quantity to confirm product suitability.

Send an Inquiry
TUZHAN Electric 1000V DC Type 2 solar surge protection device 3P

Product Overview

Photovoltaic systems contain DC circuits connected to solar modules, combiner boxes, and inverters. Transient overvoltage may enter these circuits through lightning-related surges or switching events, potentially affecting connected electrical equipment. A correctly selected Type 2 DC surge protective device helps limit transient overvoltage within the protection system.

This model is rated for 1000V DC applications and uses MOV protection elements. Its plug-in construction allows the replaceable module to be handled separately from the installed base, while the visual indicator helps technicians check the device's operating status during inspection. Confirm the system grounding arrangement and manufacturer's wiring instructions before installation.

1000V DC
Maximum continuous operating voltage (Uc)
20kA
Nominal discharge current (In)
40kA
Maximum discharge current (Imax)
≤3.8kV
Voltage protection level (Up)

Technical Specifications

Review the main electrical and installation parameters below when matching the device to a PV system. The selected surge protective device must be compatible with the actual DC voltage, grounding arrangement, and protection design.

Parameter Specification
Brand TUZHAN Electric
Model TZU-40 3P
Product Type DC Type 2 Surge Protection Device
Number of Poles 3P
Maximum Continuous Operating Voltage (Uc) 1000V DC
Nominal Discharge Current (In) 20kA (8/20μs)
Maximum Discharge Current (Imax) 40kA (8/20μs)
Voltage Protection Level (Up) ≤3.8kV
Protection Element MOV
Construction Plug-in type
Disconnection Mechanism Independent thermal disconnection
Status Indication Visual indicator
Housing Material PA66, UL94 V-0
Protection Degree IP20
Mounting 35mm DIN rail
Operating Temperature −40°C to +80°C
Protection Paths DC+ to PE; DC− to PE

Design Details

MOV Protection Element

The metal oxide varistor (MOV) responds to transient overvoltage by changing its electrical resistance and limiting the voltage across the protected circuit. Its discharge ratings should be considered together with the installation's expected surge exposure and the coordination of upstream and downstream protective devices.

Internal structure of the TZU-40 3P solar DC surge protective device
Plug-in structure of the TUZHAN Electric DC surge protection device

Plug-In Construction and Thermal Disconnection

The plug-in design separates the replaceable protection module from the installed base, which can simplify module replacement when the system has been safely isolated and the manufacturer's instructions are followed. The independent thermal disconnection mechanism is intended to disconnect the protection element when the device reaches a failure condition requiring isolation.

Visual Status Indication

The visual indicator provides a quick status reference during routine inspection. Maintenance personnel should check the indicator according to the product's marking and instructions, and replace the module when the indicated status requires it. A visual check does not replace electrical inspection or system-level maintenance.

Visual status indication on the solar DC surge protection device

Applications in Photovoltaic Systems

The device can be considered for compatible 1000V DC photovoltaic installations where Type 2 surge protection is required. Final selection depends on the system's maximum open-circuit voltage, grounding method, expected surge exposure, and the protection arrangement specified by the electrical designer.

PV Combiner Boxes

Used in suitable DC distribution arrangements to help limit transient overvoltage on photovoltaic circuits before power reaches downstream equipment.

Solar Inverter DC Circuits

Can be incorporated into a coordinated DC protection design for inverter input circuits, subject to the inverter manufacturer's requirements and system configuration.

PV Electrical Cabinets

Suitable for evaluation in solar electrical cabinets where the voltage rating, protection paths, mounting arrangement, and available installation space match the design.

How to Select the Right DC SPD

Before ordering, check the following items with your electrical design or engineering team. Selecting an SPD by voltage rating alone may not be sufficient for a complete protection solution.

Selection Item What to Confirm
System voltage Confirm that the maximum PV open-circuit voltage under the lowest expected temperature is compatible with the SPD rating.
Protection type Confirm whether Type 2 protection is suitable for the installation or whether additional protection is required by the system design.
Grounding arrangement Check the DC system topology and PE connection requirements before choosing the protection configuration.
Discharge ratings Evaluate In, Imax, and Up against the project's protection requirements and the withstand characteristics of connected equipment.
Installation space Confirm 35mm DIN rail compatibility, cabinet clearance, wiring space, and accessibility for inspection.

Installation and Maintenance

Before Installation

Verify the system voltage, polarity, grounding arrangement, and wiring diagram. Installation should be carried out by qualified personnel with the circuit isolated and all applicable safety procedures followed.

During Operation

Check the visual status indicator during scheduled maintenance. Inspect terminals and wiring for signs of loosening, overheating, or damage in accordance with the installation and maintenance plan.

When Replacement Is Needed

Isolate the circuit and follow the manufacturer's replacement procedure. Do not remove or replace a plug-in module while the circuit is energized unless the product documentation explicitly permits that operation.

Manufacturing and Quality Checks

At TUZHAN Electric, surge protective devices go through production processes that include component assembly, welding where applicable, assembly, testing, and final inspection. The specific inspection items and acceptance criteria depend on the product model and production requirements.

For project orders, buyers can provide their required model, electrical ratings, quantity, branding, and packaging details before production confirmation. If your project requires particular test documentation or additional inspection arrangements, please specify these requirements during inquiry so availability can be confirmed before ordering.

OEM and ODM Options

TUZHAN Electric supports customization for distributors, electrical brands, and project suppliers. Available options depend on the product structure and order requirements; confirm the requested changes before sample approval and bulk production.

Branding

Logo silk-screen printing and customized model identification are available for qualifying orders.

Packaging

Company and product information can be incorporated into customized packaging, subject to artwork confirmation.

Product Development

ODM discussions can cover parameters, socket layout, color, and other product details subject to technical evaluation.

MOQ, Lead Time and Shipping

For an accurate quotation, please provide the model, quantity, destination country, branding requirements, and packaging details. Lead time may vary with stock availability, order quantity, and customization scope.

Order Item Reference Information
Standard MOQ 50 pcs per model
Stock orders: 50–500 pcs Approximately 3–7 days, subject to stock confirmation
Stock orders: 500–5,000 pcs Approximately 7–15 days, subject to stock and production schedule
OEM orders Approximately 12–18 days, depending on order details
ODM orders Approximately 40 days for mold confirmation and 15 days for production; actual schedule requires confirmation
Shipping Terms FOB Ningbo/Wenzhou, CIF, and door-to-door air shipping options

Need a DC Surge Protection Solution for Your Solar Project?

Send your system voltage, wiring configuration, target quantity, and destination market to TUZHAN Electric. Our team can help check the model information and confirm quotation, availability, and customization details.

Request a Quote

Frequently Asked Questions

What is a Type 2 DC surge protective device used for?

A Type 2 DC SPD helps limit transient overvoltage in compatible DC electrical systems. In photovoltaic installations, it is selected as part of a coordinated protection design for circuits such as PV combiner boxes and inverter inputs.

Can this model be used in a 1000V DC solar system?

The model is specified for 1000V DC applications. Before installation, confirm the maximum system open-circuit voltage under the expected operating temperature, the grounding arrangement, and the required protection configuration with the electrical designer.

What do In 20kA and Imax 40kA mean?

In is the nominal discharge current rating, while Imax is the maximum discharge current rating, both specified here with an 8/20μs waveform. These ratings should be evaluated alongside the voltage protection level and the installation's overall surge protection design.

Does the product support OEM branding?

Yes. TUZHAN Electric supports logo silk-screen printing and customized packaging for qualifying orders. Standard logo customization has a reference MOQ of 200 pcs; confirm artwork, model identification, and packaging requirements before placing the order.

What is the standard MOQ?

The standard MOQ is 50 pcs per model. Customized orders may have different requirements depending on the requested changes, so confirm the quantity and customization details with the sales team.

What warranty and technical support are available?

TUZHAN Electric provides a two-year warranty for component quality and online technical support. Please share the product model, installation conditions, and issue details when requesting technical assistance.

Request Product Information and Pricing

For a quotation, please include the following information in your inquiry:

  • Required model and quantity
  • DC system voltage and application
  • Destination country and preferred shipping terms
  • OEM logo, packaging, or other customization requirements
  • Any required technical documents or inspection conditions

Our team will review the submitted information and confirm product suitability, stock status, lead time, and quotation details.

Contact TUZHAN Electric

Warranty: 2 years for component quality. Online technical support is available.

Send Inquiry
Contact Info
Send your product requirements, target specifications and order quantities to discuss suitable electrical protection products, quotations and production arrangements with our team.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
RejectAccept