The 1000V DC Type 2 Solar Surge Protection Device 3P is designed for photovoltaic DC circuits that require protection against transient overvoltage. With a plug-in structure and visual status indication, it supports installation and maintenance in solar combiner boxes, inverter DC circuits, and PV electrical cabinets.
TUZHAN Electric supplies standard products and supports OEM and ODM requirements for electrical protection projects. Contact us with your system voltage, circuit configuration, and required quantity to confirm product suitability.
Send an Inquiry
Photovoltaic systems contain DC circuits connected to solar modules, combiner boxes, and inverters. Transient overvoltage may enter these circuits through lightning-related surges or switching events, potentially affecting connected electrical equipment. A correctly selected Type 2 DC surge protective device helps limit transient overvoltage within the protection system.
This model is rated for 1000V DC applications and uses MOV protection elements. Its plug-in construction allows the replaceable module to be handled separately from the installed base, while the visual indicator helps technicians check the device's operating status during inspection. Confirm the system grounding arrangement and manufacturer's wiring instructions before installation.
Review the main electrical and installation parameters below when matching the device to a PV system. The selected surge protective device must be compatible with the actual DC voltage, grounding arrangement, and protection design.
| Parameter | Specification |
|---|---|
| Brand | TUZHAN Electric |
| Model | TZU-40 3P |
| Product Type | DC Type 2 Surge Protection Device |
| Number of Poles | 3P |
| Maximum Continuous Operating Voltage (Uc) | 1000V DC |
| Nominal Discharge Current (In) | 20kA (8/20μs) |
| Maximum Discharge Current (Imax) | 40kA (8/20μs) |
| Voltage Protection Level (Up) | ≤3.8kV |
| Protection Element | MOV |
| Construction | Plug-in type |
| Disconnection Mechanism | Independent thermal disconnection |
| Status Indication | Visual indicator |
| Housing Material | PA66, UL94 V-0 |
| Protection Degree | IP20 |
| Mounting | 35mm DIN rail |
| Operating Temperature | −40°C to +80°C |
| Protection Paths | DC+ to PE; DC− to PE |
The metal oxide varistor (MOV) responds to transient overvoltage by changing its electrical resistance and limiting the voltage across the protected circuit. Its discharge ratings should be considered together with the installation's expected surge exposure and the coordination of upstream and downstream protective devices.
The plug-in design separates the replaceable protection module from the installed base, which can simplify module replacement when the system has been safely isolated and the manufacturer's instructions are followed. The independent thermal disconnection mechanism is intended to disconnect the protection element when the device reaches a failure condition requiring isolation.
The visual indicator provides a quick status reference during routine inspection. Maintenance personnel should check the indicator according to the product's marking and instructions, and replace the module when the indicated status requires it. A visual check does not replace electrical inspection or system-level maintenance.
The device can be considered for compatible 1000V DC photovoltaic installations where Type 2 surge protection is required. Final selection depends on the system's maximum open-circuit voltage, grounding method, expected surge exposure, and the protection arrangement specified by the electrical designer.
Used in suitable DC distribution arrangements to help limit transient overvoltage on photovoltaic circuits before power reaches downstream equipment.
Can be incorporated into a coordinated DC protection design for inverter input circuits, subject to the inverter manufacturer's requirements and system configuration.
Suitable for evaluation in solar electrical cabinets where the voltage rating, protection paths, mounting arrangement, and available installation space match the design.
Before ordering, check the following items with your electrical design or engineering team. Selecting an SPD by voltage rating alone may not be sufficient for a complete protection solution.
| Selection Item | What to Confirm |
|---|---|
| System voltage | Confirm that the maximum PV open-circuit voltage under the lowest expected temperature is compatible with the SPD rating. |
| Protection type | Confirm whether Type 2 protection is suitable for the installation or whether additional protection is required by the system design. |
| Grounding arrangement | Check the DC system topology and PE connection requirements before choosing the protection configuration. |
| Discharge ratings | Evaluate In, Imax, and Up against the project's protection requirements and the withstand characteristics of connected equipment. |
| Installation space | Confirm 35mm DIN rail compatibility, cabinet clearance, wiring space, and accessibility for inspection. |
Verify the system voltage, polarity, grounding arrangement, and wiring diagram. Installation should be carried out by qualified personnel with the circuit isolated and all applicable safety procedures followed.
Check the visual status indicator during scheduled maintenance. Inspect terminals and wiring for signs of loosening, overheating, or damage in accordance with the installation and maintenance plan.
Isolate the circuit and follow the manufacturer's replacement procedure. Do not remove or replace a plug-in module while the circuit is energized unless the product documentation explicitly permits that operation.
At TUZHAN Electric, surge protective devices go through production processes that include component assembly, welding where applicable, assembly, testing, and final inspection. The specific inspection items and acceptance criteria depend on the product model and production requirements.
For project orders, buyers can provide their required model, electrical ratings, quantity, branding, and packaging details before production confirmation. If your project requires particular test documentation or additional inspection arrangements, please specify these requirements during inquiry so availability can be confirmed before ordering.
TUZHAN Electric supports customization for distributors, electrical brands, and project suppliers. Available options depend on the product structure and order requirements; confirm the requested changes before sample approval and bulk production.
Logo silk-screen printing and customized model identification are available for qualifying orders.
Company and product information can be incorporated into customized packaging, subject to artwork confirmation.
ODM discussions can cover parameters, socket layout, color, and other product details subject to technical evaluation.
For an accurate quotation, please provide the model, quantity, destination country, branding requirements, and packaging details. Lead time may vary with stock availability, order quantity, and customization scope.
| Order Item | Reference Information |
|---|---|
| Standard MOQ | 50 pcs per model |
| Stock orders: 50–500 pcs | Approximately 3–7 days, subject to stock confirmation |
| Stock orders: 500–5,000 pcs | Approximately 7–15 days, subject to stock and production schedule |
| OEM orders | Approximately 12–18 days, depending on order details |
| ODM orders | Approximately 40 days for mold confirmation and 15 days for production; actual schedule requires confirmation |
| Shipping Terms | FOB Ningbo/Wenzhou, CIF, and door-to-door air shipping options |
Send your system voltage, wiring configuration, target quantity, and destination market to TUZHAN Electric. Our team can help check the model information and confirm quotation, availability, and customization details.
Request a QuoteA Type 2 DC SPD helps limit transient overvoltage in compatible DC electrical systems. In photovoltaic installations, it is selected as part of a coordinated protection design for circuits such as PV combiner boxes and inverter inputs.
The model is specified for 1000V DC applications. Before installation, confirm the maximum system open-circuit voltage under the expected operating temperature, the grounding arrangement, and the required protection configuration with the electrical designer.
In is the nominal discharge current rating, while Imax is the maximum discharge current rating, both specified here with an 8/20μs waveform. These ratings should be evaluated alongside the voltage protection level and the installation's overall surge protection design.
Yes. TUZHAN Electric supports logo silk-screen printing and customized packaging for qualifying orders. Standard logo customization has a reference MOQ of 200 pcs; confirm artwork, model identification, and packaging requirements before placing the order.
The standard MOQ is 50 pcs per model. Customized orders may have different requirements depending on the requested changes, so confirm the quantity and customization details with the sales team.
TUZHAN Electric provides a two-year warranty for component quality and online technical support. Please share the product model, installation conditions, and issue details when requesting technical assistance.
For a quotation, please include the following information in your inquiry:
Our team will review the submitted information and confirm product suitability, stock status, lead time, and quotation details.
Contact TUZHAN ElectricWarranty: 2 years for component quality. Online technical support is available.
Address
No.51, Changjiang Road, Wenzhou Bridge Industrial Zone, Beibaixiang Town, Yueqing City, Zhejiang Province, China
Tel