The TU-SHAN Electric TZU-40 is a 2-pole Type 2 DC surge protection device designed for compatible 500VDC photovoltaic systems. It helps limit transient overvoltages caused by induced lightning and switching events, diverting surge current toward protective earth (PE) to reduce the risk of damage to solar inverters and other connected equipment.
Built around metal oxide varistors (MOVs), the device combines 20kA nominal discharge current, 40kA maximum discharge current, plug-in protection modules and visual status indication. Its 35mm DIN rail mounting supports installation in suitable PV combiner boxes and inverter cabinets, making it a practical option for solar system integrators, electrical distributors and panel builders.
The 500V DC Type 2 Solar Surge Protection Device 2P is intended for secondary surge protection, not as a stand-alone solution for direct lightning-current protection. Confirm the system voltage, earthing arrangement and required protection coordination before ordering.
| Parameter | Specification |
|---|---|
| Brand | TU-SHAN Electric |
| Model | TZU-40 |
| Product Type | Type 2 DC Surge Protection Device |
| Intended Application | Compatible photovoltaic DC systems |
| Rated System Voltage | 500V DC |
| Configuration | 2P |
| Maximum Continuous Operating Voltage (Uc) | 500V DC |
| Nominal Discharge Current (In, 8/20 μs) | 20kA |
| Maximum Discharge Current (Imax, 8/20 μs) | 40kA |
| Voltage Protection Level (Up) | ≤1.7kV |
| Protection Element | Metal oxide varistor (MOV) |
| Protection Modes | DC+ to PE and DC− to PE, subject to confirmation against the product wiring diagram |
| Thermal Protection | Integrated thermal disconnection |
| Status Indication | Visual status indicator on each module |
| Housing Material | PA66, UL94 V-0 flame-retardant grade |
| Mounting | 35mm DIN rail |
| Protection Rating | IP20 |
| Operating Temperature | -40°C to +85°C |
| Installation Environment | Inside a suitable enclosure |
| Optional Accessories | DC-specific backup protection device (SCB) and grounding copper bar, subject to project requirements |
Under normal operating conditions, the MOV elements remain in a high-resistance state, allowing the photovoltaic circuit to operate without materially affecting normal power transmission.
When an induced lightning surge or switching transient raises the voltage, the MOV elements conduct and divert surge current through the designated protective earthing path. This limits transient voltage across the protected circuit. The specified Up value of ≤1.7kV applies under the relevant test conditions and should be assessed alongside the withstand capability of the equipment being protected.
The intended protection paths and terminal arrangement must match the wiring diagram supplied for the selected model. Correct PE connection and suitable installation wiring are essential to effective surge protection.
Repeated surge exposure and MOV ageing can increase leakage current and temperature. The integrated thermal disconnection mechanism is designed to disconnect an affected protection element under its specified operating conditions. The visual indicator helps maintenance personnel identify a module that requires inspection.
Check the status indicator during routine maintenance. If a module shows a fault indication, isolate the circuit safely and follow the manufacturer's replacement procedure. Do not assume the remaining protection module provides complete protection after a fault.
The 500V DC operating rating supports use in compatible photovoltaic circuits. Before selection, calculate the PV array's maximum open-circuit voltage at the lowest expected temperature and verify that it remains within the applicable device rating.
The nominal discharge current is 20kA and the maximum discharge current is 40kA, both specified with an 8/20 μs waveform. These figures describe surge-current performance under applicable test conditions; they do not by themselves establish suitability for every lightning exposure level.
The plug-in construction allows an affected module to be replaced separately where permitted by the manufacturer's instructions. This can simplify maintenance without requiring removal of the complete base assembly.
Each protection module incorporates a thermal disconnection mechanism. Visual status indication helps technicians check the condition of the SPD during scheduled inspection.
The compact 2P design supports installation in compatible PV combiner boxes and inverter cabinets. Check the available panel space, terminal access and required wiring clearance before installation.
The housing is specified as PA66 with a UL94 V-0 flame-retardant classification. The classification applies to the housing material under the relevant test method and does not mean the complete SPD is fireproof.
The TZU-40 can be evaluated for compatible PV DC circuits where secondary surge protection is required. Final suitability depends on the circuit design, installation conditions and applicable electrical standards.
A Type 2 DC SPD is one part of a photovoltaic system's surge protection arrangement. Correct device selection, installation location, wiring and coordination with other protective devices all affect the protection achieved.
A complete PV installation may use DC-side SPDs, AC-side SPDs and other protective devices. The required arrangement depends on the specific installation; one universal configuration is not suitable for every project.
When evaluating a DC SPD for a solar project, buyers should review the product specification and request supporting records relevant to the intended application. The manufacturer's stated quality control procedures include checks for incoming components, protection performance and finished-product condition.
Incoming MOV elements are subject to inspection and the surge or environmental tests specified in the manufacturer's quality plan.
Thermal disconnection performance is checked according to the manufacturer's test procedures to assess operation under specified conditions.
Depending on the product specification and inspection plan, checks may include electrical withstand testing, voltage protection performance verification and visual status indicator inspection.
The declared PA66 material and UL94 V-0 classification should be supported by appropriate material documentation where required for project approval.
Where maintained by the manufacturer, production and inspection records can support batch traceability. Third-party reports or certification documents should be reviewed by their actual issuing body, report number, applicable standard and scope. Availability and coverage should be confirmed for the specific model before a purchase order is finalized.
The TZU-40 described here is a Type 2 DC surge protection device for compatible 500VDC photovoltaic circuits. Do not use it on an AC circuit unless the manufacturer explicitly confirms a separate model with the appropriate AC rating.
Uc is the maximum continuous operating voltage specified for the SPD. The PV system's maximum open-circuit voltage, including temperature-related increases, must be checked before selecting the device.
In is the nominal discharge current and Imax is the maximum discharge current, both specified with an 8/20 μs waveform. Their interpretation and suitability should be checked against the applicable product standard and test documentation.
No. Its IP20 rating is intended for protected installation inside a suitable enclosure. The enclosure must provide the environmental protection required at the installation site.
Type 2 SPDs are primarily intended for transient surge protection, including induced lightning surges. They should not be treated as a stand-alone solution for direct lightning-current protection. Where required, Type 1 SPDs and a properly designed external lightning protection system should be considered.
The requirement depends on the SPD manufacturer's instructions, the applicable installation standard and the system's fault-current conditions. Where backup protection is required, it must be suitable for DC operation and coordinated with the SPD.
Arrange an inspection and replace the affected module if required. Isolate the circuit safely and follow the manufacturer's instructions. Do not assume the remaining module provides complete protection after a fault.
The plug-in design supports separate module replacement where permitted by the manufacturer's instructions. Isolate the equipment and follow the specified replacement procedure before maintenance.
Provide the required quantity, PV system voltage, maximum open-circuit voltage, installation location, required configuration, destination country and applicable project standards. Include certification or test-report requirements and details of the proposed DC backup protection device where available.
When sourcing the 500V DC Type 2 Solar Surge Protection Device 2P, confirm the electrical ratings and installation requirements before finalizing the model. Providing the project details with your inquiry helps the sales team assess the required configuration and documentation more efficiently.
Contact TU-SHAN Electric for product details and a quotation. Confirm the model configuration, applicable technical documents and any project-specific requirements before placing your order.