English
Products
1P+N Type 1+Type 2 Surge Protection Device
  • 1P+N Type 1+Type 2 Surge Protection Device1P+N Type 1+Type 2 Surge Protection Device
  • 1P+N Type 1+Type 2 Surge Protection Device1P+N Type 1+Type 2 Surge Protection Device
  • 1P+N Type 1+Type 2 Surge Protection Device1P+N Type 1+Type 2 Surge Protection Device
  • 1P+N Type 1+Type 2 Surge Protection Device1P+N Type 1+Type 2 Surge Protection Device

1P+N Type 1+Type 2 Surge Protection Device

The TZB+C-50 1P+N Type 1+Type 2 Surge Protection Device (SPD) combines Type 1 and Type 2 protection in a single modular unit for single-phase 220V AC distribution systems. It is designed to handle lightning-related surge currents as well as transient overvoltages, making it a practical option for installations that require both levels of surge protection in one device.

As an established Manufacturer and Factory Direct Supplier in China, we offer Wholesale electrical protection solutions. The TU-SHAN Electric TZB+C-50 1P+N is a combined Type 1+Type 2 AC surge protective device engineered for compatible single-phase distribution systems. Its compact two-module configuration combines an L-pole module and an N-PE module within a space-saving DIN-rail assembly designed for modern building distribution boards, electrical equipment rooms, and AC power cabinets.

For international electrical distributors, panel builders, and project procurement buyers, key selection criteria include impulse-current capacity, operating voltage, earthing arrangement, and coordination with upstream protection. This High-Performance 1P+N Type 1+Type 2 Surge Protection Device delivers Durable operation specified with Iimp 5kA, In 30kA, Imax 50kA, and Up ≤1.5kV. Built under rigorous Quality standards and backed by a 2 Years Warranty, it provides reliable defense. Check our model-specific datasheet to confirm the rating basis for your intended installation.

Both plug-in modules feature a clear visual status indicator and an integrated thermal disconnection mechanism. The assembly is engineered for standard 35mm DIN-rail mounting inside any suitable electrical enclosure. Furthermore, our OEM and Customized service capabilities ensure that electrical contractors receive tailored configurations backed by professional factory support.

TUZHAN Electric TZB+C-50 1P+N combined Type 1 and Type 2 AC surge protective device
TZB+C-50 single-phase AC surge protector with two plug-in modules

Technical Specifications

Review the following technical parameters when pairing the TZB+C-50 1P+N with your Distribution Box requirements. Always confirm electrical compatibility and protective-device coordination alongside an appropriate Miniature Circuit Breaker before completing bulk orders.

BrandTU-SHAN Electric (Made in China Factory)
ModelTZB+C-50 1P+N
Product typeCombined Type 1+Type 2 AC surge protective device
Rated application systemSingle-phase AC 220V
Frequency50/60Hz
Module configuration1 × TZB+C-50 L-pole module + 1 × TZB+C-50 N-PE module
L-pole continuous operating voltage ($U_c$)275V AC
N-PE module continuous operating voltage ($U_c$)255V AC
Impulse current ($I_{imp}$)5kA, 10/350 μs
Nominal discharge current ($I_n$)30kA, 8/20 μs
Maximum discharge current ($I_{max}$)50kA, 8/20 μs
Voltage protection level ($U_p$)≤1.5kV
Protection pathsL-PE and N-PE
Disconnection mechanismThermal disconnection for each module
Status indicationIndividual visual indicators
Housing materialPA66
Flame-retardant ratingUL94 V-0, as specified
Operating temperature-40°C to +80°C, as specified
Mounting35mm DIN rail
Protection ratingIP20
Earthing configurationTN-S listed as recommended; verify installation compatibility
Related accessoriesSPD Surge Backup Protector (SCB) and grounding busbar

Technical note: $I_{imp}$, $I_n$, $I_{max}$, and $U_p$ describe distinct electrical characteristics. Confirm whether each value applies to an individual module, a protection mode, or the complete assembly by consulting our latest factory test documentation.

Key Selection Points for Single-Phase Protection

1. Select the Required Surge-Current Ratings

Type 1 and Type 2 classifications correspond to different surge-current test protocols. The 10/350 μs waveform evaluates Type 1 impulse current performance, while the 8/20 μs waveform tests Type 2 discharge behavior.

Our TZB+C-50 1P+N is rated at $I_{imp}$ 5kA, $I_n$ 30kA, and $I_{max}$ 50kA. Required ratings depend on lightning exposure and building specifications.

2. Verify Voltage and Earthing Compatibility

Engineered for single-phase AC 220V networks, featuring $U_c$ values of 275V AC for the L-pole and 255V AC for the N-PE module.

Always verify phase-to-earth voltages, neutral configurations, and prospective temporary overvoltages prior to finalizing procurement specifications.

3. Consider Inspection and Module Replacement

Each plug-in module incorporates an independent visual status indicator and thermal disconnection mechanism to facilitate routine facility maintenance.

Always isolate circuits safely before performing module swaps. Ensure replacements match exact manufacturer specifications.

4. Allow Space for Wiring and Enclosure Protection

Designed for standard 35mm DIN-rail mounting inside compatible electrical enclosures, ensuring clean conductor routing and terminal access.

The IP20-rated unit requires mounting within a protective enclosure suited to the installation's environmental conditions.

Typical Applications

Building Distribution Boards

Ideal for single-phase distribution boards supplying lighting, socket circuits, and commercial services where combined Type 1 and Type 2 Surge Protection Device solutions are required.

Equipment Rooms and UPS Cabinets

Protects sensitive UPS systems, monitoring hardware, and server room power feeds against transient switching overvoltages.

Solar AC Distribution Cabinets

Suited for single-phase AC distribution lines in photovoltaic systems. Note that this is an AC SPD; PV strings require our dedicated DC surge protection line.

Communication and Monitoring Power Supplies

Safeguards access control, CCTV, and telecommunication power feeds against induced surges when paired with proper earthing.

How the SPD Works in a Distribution System

During Normal Operation

The SPD remains in standby mode under normal operating voltages, presenting high impedance without disrupting power flow.

When a Surge Occurs

Upon detecting a qualifying transient or lightning surge, internal varistors conduct current through designated paths, clamping $U_p$ to $\le 1.5\text{ kV}$.

When a Module Requires Attention

Following heavy surge exposure, thermal disconnectors safely isolate degraded elements while visual flags alert maintenance teams.

Coordination with Backup Protection

Proper coordination with upstream SCB backup protectors ensures complete circuit safety and selective interruption during heavy fault currents.

TUZHAN Electric TZB+C-50 1P+N surge protection module details
TZB+C-50 single-phase AC surge protective device for DIN-rail distribution cabinets

Installation Checks Before Ordering

Verify these core parameters with our technical sales team before finalizing your wholesale procurement:

  • Supply voltage: Confirm nominal AC voltage, frequency, and phase parameters.
  • Earthing arrangement: Ensure TN-S or compatible earthing structures match L-PE and N-PE paths.
  • Surge-current requirements: Match impulse ratings against structural lightning protection standards.
  • Backup protection: Verify required SCB backup devices for fault coordination.
  • Wiring and terminals: Adhere to specified torque ratings and conductor cross-sections.
  • Enclosure rating: House the IP20 unit within appropriate protective enclosures.
  • Maintenance clearance: Ensure visual status indicators remain easily accessible.

Proper installation guarantees long-term operational safety and full compliance with engineering standards.

Manufacturing and Quality Control

WENZHOU TUSH-AN ELECTRIC CO., LTD, established in 2018, leverages over 20 years of expert engineering experience in low-voltage electrical protection, specializing in SPDs, SCBs, and circuit breakers. Our automated Factory is equipped with advanced machinery including glue-filling systems, automatic welding units, and precision testing stations, achieving a robust monthly output of 100,000 units.

Every batch undergoes stringent multi-stage inspection adhering to IEC 61643-11 and GB/T 18802.1 standards to guarantee uncompromised field reliability.

TUZHAN Electric low-voltage electrical product manufacturing facility
TUZHAN Electric electrical product assembly and production equipment

Wholesale Supply and OEM Options

We provide flexible Wholesale supply terms and comprehensive OEM customization services for global electrical partners.

Purchasing Item General Terms & Lead Times
Standard Model MOQ 50 units per model
Sample Evaluation 1–10 units available for testing (freight collect)
OEM Logo Printing MOQ 200 units with custom branding options
Housing / Circuit Modification MOQ 1,000 units (subject to engineering review)
Stocked Order Dispatch Approx. 3–7 days for 50–500 units
Standard Production Orders Approx. 7–15 days for 500–5,000 units
OEM Custom Orders Approx. 12–18 days for branded production
ODM / Tooling Projects Approx. 40 days tooling setup + 15 days production
Shipping Terms FOB Ningbo / Wenzhou, CIF, or custom EXW terms
Warranty & Support Comprehensive 2 Years Warranty

Contact our export department to discuss bespoke packaging, laser logo engraving, and specialized regional compliance requirements.

Frequently Asked Questions

What is a 1P+N Type 1+Type 2 Surge Protection Device?

It is a combined modular surge arrester utilizing an L-pole and an N-PE module to handle both high-energy lightning currents and switching overvoltages in single-phase systems.

Is the TZB+C-50 1P+N suitable for standard 220V supplies?

Yes, it is specifically rated for single-phase AC 220V networks, featuring robust $U_c$ thresholds of 275V (L-pole) and 255V (N-PE).

What is the difference between Iimp, In, and Imax?

$I_{imp}$ measures 10/350μs lightning impulse current tolerance, $I_n$ represents nominal 8/20μs discharge current, and $I_{max}$ denotes peak 8/20μs surge capacity.

Can individual modules be replaced?

Yes, our plug-in modular design allows safe, straightforward individual module replacement upon end-of-life indication without rewiring the base.

Does this SPD require a separate SCB backup protector?

Depending on prospective short-circuit levels, pairing with a matching SCB surge backup protector is recommended for optimal coordination.

Can this unit be installed in outdoor enclosures?

With an IP20 rating, it must be installed inside a weather-resistant electrical enclosure shielded from direct moisture and dust.

Is it compatible with solar PV DC systems?

No, this is an AC-rated device. Solar DC arrays require specialized photovoltaic DC surge protective devices.

How do I request a factory wholesale quotation?

Provide your target order quantity, destination port, electrical specifications, and OEM branding needs to receive a prompt factory-direct quote.

Request Factory Direct Pricing & Samples

Sourcing a reliable 1P+N Type 1+Type 2 Surge Protection Device for your upcoming electrical projects? Partner with TU-SHAN Electric for Affordable wholesale rates, OEM flexibility, and dependable technical support.

Contact our engineering sales team today to discuss bulk quantities, custom packaging, and project-specific technical documentation.

Send Inquiry
Contact Info
Send your product requirements, target specifications and order quantities to discuss suitable electrical protection products, quotations and production arrangements with our team.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
RejectAccept