The TZB+C-50 3P+N Type 1+Type 2 Surge Protection Device is designed for three-phase 380V AC power distribution systems. Its combined T1+T2 configuration integrates Type 1 and Type 2 surge protection functions in one four-module assembly, making it suitable for specified three-phase power entry applications in industrial plants, commercial buildings, data centers, and photovoltaic AC distribution cabinets.

As a professional China manufacturer and factory, we develop and produce the TU-SHAN TZB+C-50 3P+N combined Type 1 and Type 2 surge protective device. Made in China, this durable, high-performance SPD is built for three-phase AC distribution systems. We support wholesale, customized and OEM orders with affordable factory direct pricing, and every unit is covered by our 2 years warranty.

This 3P+N Type 1+Type 2 Surge Protection Device adopts three phase protection modules plus one neutral-to-earth module. Its pluggable module design, standalone visual status indicator and built-in thermal disconnection simplify maintenance work for electrical contractors, panel builders and distributors. If you also need single phase version, check our 1P+N Type 1+Type 2 SPD.

We strictly follow IEC 61643-11 and GB/T 18802.1 standards during production. Before you confirm the purchase, we recommend matching the earthing system, actual working voltage and surge current level with your project specification. You can also pair this SPD with our SPD surge backup protector for full protection coordination.

3P+N Type 1+Type 2 SPD Technical Specifications For Your Project Selection

Item Specification
Brand TU-SHAN Electric
Model TZB+C-50 3P+N
Product type Combined Type 1+Type 2 AC SPD
Rated application system Three-phase AC 380V
Frequency 50/60Hz
Module configuration 3 × TZB+C-50 L-pole modules + 1 × TZB+C-50 N-PE module
L-pole continuous operating voltage (Uc) 275V AC
N-PE module continuous operating voltage (Uc) 255V AC
Impulse current (Iimp) 5kA, 10/350 μs
Nominal discharge current (In) 30kA, 8/20 μs
Maximum discharge current (Imax) 50kA, 8/20 μs
Voltage protection level (Up) ≤1.5kV
Protection paths L1-PE, L2-PE, L3-PE and N-PE
Disconnection mechanism Thermal disconnection for each module
Status indication Individual visual indicators
Housing material PA66
Flame-retardant rating UL94 V-0, as specified
Operating temperature -40°C to +80°C, as specified
Mounting 35mm DIN rail
Protection rating IP20
Earthing system TN-S compatibility to be verified against the installation
Compatible accessories SPD backup protector (SCB) and grounding busbar, subject to system requirements

Technical note: Confirm whether Iimp, In, Imax and Up are specified per pole, per protection mode or for the complete assembly using the model-specific datasheet and supporting test documentation. Final engineering selection must follow the verified ratings.

Core Advantages Of Our Durable 3P+N Type1+Type2 Surge Protection Device

Dual Type 1 + Type 2 Surge Protection

Our high-performance TZB+C-50 3P+N integrates Type 1 and Type 2 surge protection into one unit. It handles 10/350μs lightning impulse current and 8/20μs switching surge current together. This combined SPD simplifies cabinet layout for main incoming protection and helps buyers reduce procurement costs.

3P+N Four-Wire Protection Layout

Three phase modules plus one N-PE module deliver full L1-PE, L2-PE, L3-PE and N-PE protection paths, perfectly matching standard three-phase four-wire 380V power distribution. We check every module’s Uc rating strictly before shipment to guarantee stable operation.

Replaceable Plug-In Modules

Each independent module carries visual status indication and thermal cut-off. Maintenance teams only replace the failed module instead of the whole SPD. This design cuts your after-sales maintenance cost and downtime for long-term projects.

Standard DIN Rail Mount & Stable Build

Designed for universal 35mm DIN rail installation inside distribution enclosures. The flame retardant PA66 housing makes this SPD durable against harsh indoor electrical environments. Panel builders can install it fast together with our miniature circuit breaker.

Typical Application Scenarios For This 3P+N Type1+Type2 SPD

Industrial Main Distribution Cabinets

Factory three-phase distribution boards for production lines, motors and control panels. Wholesale buyers and electrical contractors often select this SPD as primary lightning surge protection at factory power entry points.

Commercial Building Switchboards

Office buildings, shopping malls and hotels with HVAC, lift and lighting three-phase loads. Our affordable factory direct SPD is widely used for commercial electrical safety upgrade projects.

Data Center & UPS Power Cabinets

Server room UPS distribution systems and monitoring equipment need reliable overvoltage suppression. We can provide customized marking and packaging for large data center project orders.

Grid-Tied PV AC Side Distribution

It works for AC output cabinet of commercial solar systems. Please note this AC SPD cannot replace dedicated solar DC surge protection device on PV string sides.

VFD & Motor Control Cabinets

Variable frequency drive and heavy motor control cabinets suffer frequent switching surges. This high-performance SPD protects expensive drive boards from transient voltage damage.

Working Principle & Protection Logic

The TZB+C-50 series adopts combined spark gap and voltage limiting protection technology. Under normal grid voltage, the protection components stay off-state. Once lightning surge or switching transient hits, the SPD rapidly conducts surge current to earth and clamps residual voltage below ≤1.5kV to shield downstream electrical equipment.

Every module comes with independent thermal disconnection to avoid fire risk under abnormal overheating. Visual windows offer local inspection, but regular electrical testing is still required for critical installations.

Please understand the SPD works as one part of the whole protection system. It cannot substitute circuit breakers, SCB backup protection and qualified earthing network.

Installation Guidance & Protection Coordination Tips

Work with your electrical engineer or panel builder and check these points before ordering or installing our 3P+N Type1+Type2 SPD:

  • Supply voltage: Confirm three-phase system voltage, phase-earth voltage and 50/60Hz frequency.
  • Earthing arrangement: Verify TN-S or other grounding system compatibility on site.
  • Surge rating requirement: Match Iimp, In, Imax with your lightning protection design and datasheet.
  • Backup protection: Select matched SCB according to short-circuit current and coordination curve.
  • Wiring & grounding: Follow official wiring drawing, keep short leads and use proper cable size.
  • Enclosure: Install this IP20 SPD inside a suitable electrical cabinet to avoid dust and moisture.
  • Maintenance access: Reserve enough cabinet space for module inspection and replacement.

Our Factory Strength & Quality Control

Wenzhou Tush-An Electric Co.,Ltd was founded in 2018. Our team owns over 20 years of low voltage electrical R&D and manufacturing experience. Our product portfolio covers SPD, SCB, MCB and distribution boxes.

We are a real factory equipped with automatic welding machines, glue filling equipment and professional testing benches. Our monthly total production capacity can reach around 100,000 units. All finished SPDs pass functional testing before packing.

We manufacture our Made in China SPD referring to IEC 61643-11 and GB/T 18802.1. For wholesale buyers and project contractors, we provide test reports, datasheets and supporting certification documents upon request.

Wholesale, OEM & Customized Order Terms

Purchasing item General terms
Standard model MOQ 50 units per model
Samples 1–10 units; sample availability and free-sample eligibility to be confirmed. Freight is generally collected.
Logo printing (OEM) MOQ 200 units
Housing or circuit modifications (Customized) MOQ 1,000 units, subject to technical review
Qualified stocked orders Approximately 3–7 days for dispatch for orders of 50–500 units
Standard production orders Approximately 7–15 days for qualifying orders of 500–5,000 units
OEM logo-printing orders Approximately 12–18 days
ODM or tooling projects Approximately 40 days for tooling confirmation plus 15 days for mass production, subject to project approval
Shipping terms FOB Ningbo or Wenzhou, CIF and other agreed arrangements
Warranty Two-year manufacturer's warranty, subject to applicable terms

Our OEM and customized service includes private logo, custom model code, special packaging and full set export documents. Any structural or circuit change will go through technical evaluation and extra testing before mass manufacturing.

We support stable long-term supply for electrical distributors and importers. You can send your target specification, packaging requirement and delivery schedule in advance for a smooth bulk order arrangement.

Frequently Asked Questions From Our Wholesale Buyers

1. What does 3P+N mean for this surge protective device?

3P+N means three phase protection modules plus one neutral-earth module. This TZB+C-50 3P+N SPD provides L1-PE, L2-PE, L3-PE and N-PE protection paths for three-phase four-wire AC systems.

2. What is the difference between Type 1 and Type 2 surge protection?

Type 1 is designed for lightning impulse 10/350μs current; Type 2 is for switching surge 8/20μs current. Our combined Type1+Type2 SPD covers both protection demands within one unit.

3. Is this model suitable for a 380V three-phase system?

It is designed for 380V three-phase AC system. Still you must verify phase-earth voltage, Uc rating, earthing system and TOV condition before installation.

4. What do Iimp, In and Imax mean?

Iimp is lightning impulse current (10/350μs). In is nominal discharge current and Imax is maximum discharge current (8/20μs). Check datasheet to confirm rating definition per module or whole assembly.

5. Does the TZB+C-50 3P+N require an SCB?

SCB backup protector may be required according to prospective short circuit current and SPD coordination requirement. We can recommend matched SCB when you send inquiry.

6. Can I replace one module without replacing the complete SPD?

Yes, plug-in module design supports single module replacement. Cut off power supply fully and use compatible spare module following our operation guide.

7. Can the device be installed outdoors?

No, its IP20 rating only allows indoor cabinet installation. You need an outdoor enclosure if your project works in open-air environment.

8. Can this SPD protect photovoltaic DC circuits?

No, this is AC surge protection device only. PV DC side needs dedicated DC SPD with matched DC voltage rating.

9. What information should I send for a formal quotation?

Tell us quantity, destination country, earthing type, application and OEM requirements. Project buyers can also provide lightning level and required surge ratings so we prepare accurate pricing quickly.

Request Wholesale Quotation For Our 3P+N Type1+Type2 SPD

Looking for a reliable China manufacturer of durable, high-performance 3P+N Type 1+Type 2 surge protection device with affordable factory direct price? Contact TU-SHAN for wholesale pricing, datasheet, test report and matched SCB solution.

Share your order quantity, target market and application details. If you need OEM logo or customized packaging, note your requirements in the inquiry message. Our sales team will review your requirement and send competitive quotation promptly.

Send Inquiry
Contact Info
Send your product requirements, target specifications and order quantities to discuss suitable electrical protection products, quotations and production arrangements with our team.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
RejectAccept