Type 1 AC Surge Protective Device
  • Type 1 AC Surge Protective DeviceType 1 AC Surge Protective Device
  • Type 1 AC Surge Protective DeviceType 1 AC Surge Protective Device
  • Type 1 AC Surge Protective DeviceType 1 AC Surge Protective Device

Type 1 AC Surge Protective Device

The TZU1-25 Type 1 AC Surge Protective Device (T1 SPD) is used at the incoming end of low-voltage power distribution systems to handle high-energy lightning surges. It has an impulse current rating of 25 kA (10/350 μs), a maximum continuous operating voltage of 385 V AC and a voltage protection level of ≤2.5 kV. The plug-in modules mount on a 35 mm DIN rail and can be replaced individually when required.

The TU-SHAN Electric TZU1-25 Type 1 AC Surge Protective Device 25kA 385V is designed for low-voltage AC power distribution systems that require high-energy lightning current protection at the incoming supply. With a specified impulse current (Iimp) of 25kA using the 10/350 μs waveform, it serves as the first stage of a coordinated surge protection system in installations where Type 1 protection is required by the electrical design.

The TZU1-25 supports 1P, 2P, 3P and 4P configurations, allowing the assembly to be selected according to the supply conductors and earthing arrangement. Its 35 mm DIN rail mounting suits installation inside compatible distribution cabinets. The 385V AC maximum continuous operating voltage (Uc) is an important selection parameter, but the actual system voltage and connection arrangement must be checked before choosing the device.

For projects where lightning current protection and downstream voltage limitation are both required, the TZU1-25 can be coordinated with compatible Type 2 SPDs. This staged arrangement helps address different surge protection requirements at the main distribution point and downstream circuits.

Type 1 Ac Surge Protective Device
TUZHAN Electric TZU1-25 Type 1 SPD modular structure

TZU1-25 Technical Specifications

Brand TU-SHAN Electric
Model TZU1-25
Product Type Type 1 AC Surge Protective Device
SPD Classification Type 1 (Class I)
Maximum Continuous Operating Voltage (Uc) 385V AC
Impulse Current (Iimp, 10/350 μs) 25kA
Nominal Discharge Current (In, 8/20 μs) 12.5kA
Voltage Protection Level (Up) ≤2.5kV
Protection Rating IP20
Enclosure Material V-0 flame-retardant material, as specified
Mounting 35 mm DIN rail
Single-Module Dimensions 90 × 18 × 66 mm
Available Pole Configurations 1P, 2P, 3P, 4P
Disconnection Mechanism Integrated thermal disconnector
Referenced Standards GB 18802.1, IEC 61643.1 (applicable editions and conformity documentation to be confirmed)

Specification note: Confirm the applicable standard editions, test reports, pole configuration and basis of the stated electrical ratings before using this table for project approval. Verify whether the listed impulse current, nominal discharge current and voltage protection level apply per pole or to a specified assembly.

How Type 1 Lightning Current Protection Works

A Type 1 SPD is intended for installations where the surge protection design requires the discharge of high-energy lightning current. When a qualifying transient reaches the protected AC circuit, the surge protection element conducts and diverts current toward the earthing system. The device's specified voltage protection level (Up) describes its declared limiting performance under the applicable test conditions; it should not be interpreted as a guarantee that connected equipment will experience no transient voltage.

The TZU1-25 incorporates a thermal disconnector intended to disconnect a protection element when deterioration causes an unsafe operating condition. The device and its status should be inspected in accordance with the manufacturer's instructions after a significant surge event or when abnormal operation is suspected. A module that has reached the end of its service life must be replaced using the specified procedure.

The TZU1-25 is designed for the first stage of a coordinated protection arrangement. Its stated Up of ≤2.5kV should be considered alongside the impulse withstand voltage of downstream equipment. Where a lower residual voltage is required, an appropriately selected downstream SPD may be necessary.

Typical Applications

Main Distribution Cabinets in Buildings

For commercial buildings, high-rise developments and other facilities where the lightning protection assessment calls for Type 1 protection at the incoming low-voltage supply. The final selection depends on the building's supply system, earthing arrangement and protection design.

Industrial Power Distribution

For suitable factory main distribution cabinets and industrial power distribution centers exposed to lightning-related surge risks. The TZU1-25 can form the upstream stage of a coordinated protection system serving downstream distribution circuits.

Photovoltaic Project AC Distribution

For compatible AC distribution points in photovoltaic installations where Type 1 protection is specified. The 385V AC rating does not establish suitability for DC-side PV circuits; DC applications require an SPD with the appropriate DC voltage rating and configuration.

Telecommunications and Critical Infrastructure

For suitable incoming AC power distribution points serving telecommunications facilities, data infrastructure and transportation installations where the electrical design requires Type 1 surge protection. Additional protection may be needed at downstream power distribution or equipment connection points.

Type 1 and Type 2 SPD Coordination

Type 1 and Type 2 SPDs address different stages of a surge protection system. A Type 1 device is intended to discharge high-energy lightning current using the 10/350 μs impulse waveform. A Type 2 device is generally used for additional surge protection against residual lightning-related surges and switching overvoltages, with performance evaluated using the applicable 8/20 μs waveform.

A coordinated arrangement may include:

  • Main distribution cabinet: A suitable TU-SHAN Electric TZU1-25 Type 1 SPD where lightning current protection is required.
  • Downstream distribution cabinet: A compatible Type 2 SPD selected for the circuit voltage, earthing system and required protection level.
  • Secondary distribution or terminal circuits: Additional surge protection selected according to the equipment's withstand requirements and installation conditions.

The correct combination depends on the installation design. Check the manufacturer's coordination instructions, including any specified separation distance or alternative coordination measures. The required backup fuse or circuit breaker must be selected according to the SPD documentation, prospective short-circuit current and applicable electrical installation rules.

Installation and Maintenance Considerations

The TZU1-25 is designed for parallel connection on a 35 mm DIN rail inside a suitable electrical cabinet. The selected pole configuration must match the supply conductors and earthing arrangement. IP20 is intended for protection against access to hazardous parts and solid objects within its rating; it does not indicate waterproof or outdoor suitability.

Before installation, verify the following:

  • Actual AC system voltage and compatibility with the 385V Uc rating.
  • Required pole configuration and earthing arrangement.
  • Prospective short-circuit current and specified backup protection.
  • Connection conductor sizing, routing and earthing requirements.
  • Required coordination with downstream SPDs and protected equipment.

Keep connecting conductors as short as practicable and follow the manufacturer's wiring diagram. Isolate the circuit and verify a safe working condition before inspection or module replacement. Installation and maintenance should be performed by qualified personnel in accordance with the applicable electrical safety requirements.

Technical Documentation and Quality Verification

Match Documentation to the Exact Model

For distributor supply and engineering projects, the product documentation should match the exact TZU1-25 model and pole configuration being supplied. Before submitting the device for project approval, confirm the applicable technical datasheet, wiring diagram, test documentation and conformity records.

Verify the Key Parameters

For this Type 1 SPD, the key items to verify include the 10/350 μs impulse current rating, voltage protection level, continuous operating voltage and operation of the specified disconnection mechanism. Any statements about routine factory tests, batch inspection or certification should be supported by the manufacturer's actual records.

Frequently Asked Questions

What does 25kA mean on the Type 1 AC Surge Protective Device?

The stated 25kA is the impulse current rating (Iimp) using the 10/350 μs waveform. It describes the device's specified Type 1 lightning current discharge capability under the applicable test conditions. It is not the same as the nominal discharge current In, which is specified as 12.5kA using the 8/20 μs waveform.

What is the difference between a Type 1 and a Type 2 SPD?

A Type 1 SPD is designed for lightning current discharge using the 10/350 μs waveform. A Type 2 SPD provides additional surge protection and is generally evaluated using the 8/20 μs waveform. They can be used in a coordinated arrangement when required by the electrical design.

Is the TZU1-25 suitable for 385V AC systems?

The specified maximum continuous operating voltage (Uc) is 385V AC. Suitability must still be checked against the actual system voltage, conductor arrangement, earthing system and manufacturer's connection diagram. Uc alone is not sufficient to establish compatibility with every 385V or three-phase installation.

Can the TZU1-25 protect sensitive electronic equipment on its own?

Not necessarily. Its specified voltage protection level is ≤2.5kV, and the protection required depends on the equipment's impulse withstand voltage and the installation conditions. A coordinated downstream SPD may be needed to provide additional voltage limitation closer to sensitive loads.

Does the TZU1-25 require backup overcurrent protection?

Follow the manufacturer's specified backup protection requirements. The appropriate fuse or circuit breaker depends on the SPD documentation, prospective short-circuit current and applicable installation rules. Do not select backup protection based on the 25kA impulse current rating alone.

How do I select the correct pole configuration?

The TZU1-25 is available in 1P, 2P, 3P and 4P configurations. Selection depends on the supply system, number of conductors, earthing arrangement and wiring diagram. Confirm the exact assembly and its ratings before finalizing the configuration.

Request Technical Information for TU-SHAN Electric TZU1-25

For a quotation or project evaluation, provide the required pole configuration, AC system voltage, earthing arrangement, intended application and quantity. If the SPD is part of a larger distribution project, a single-line diagram or relevant technical specification can help clarify the required protection arrangement.